GDPD-313P Yakabatwa Nemaoko Dicharge Detector
Main Host
● Ratidza: 4.3 inch color TFT LCD capacitive touch screen
● Chiratidzo chekupinza chiteshi: TEV × 1, air-coupled ultrasonic × 1
● Simba rekushandisa: DC 12V
● Musoro wefoni: 3.5mm
● Kuchengetedza data: tsigira TF kadhi yekuchengetedza uyeyakabva
● Bhatiri: 12V, 2500mAH
● Nguva yekushanda: kupfuura maawa mana
● Kurema: <1kg
● Kukura: Kukura kwemuviri: 240mm×240mm×80mm
● Kubata ukuru: 146mm×46.5mm×40mm
TEV kuyerwa
● Sensor type: capacitive coupling
● Sensor yekuisa nzira: yakavakirwa-mukati
● Frequency range: 10~100MHz
●Kuyeresa: 0~50dB
● Kururama:±1dB
● Kugadziriswa: 1dB
●Ultrasonic kuyerwa
● Sensor type: mhepo yakabatana
● Sensor tsanangudzo: yakavakirwa-mukati
● Resonance frequency: 40kHz±1kHz
● Kuyera chiyero: -10dBuV~70dBuV
● Sensitivity: -68dB (pa40.0kHz, 0dB=1 Volt/μbarrms SPL)
● Kururama:±1dB
● Kugadziriswa: 1dB
Magetsi
● Nguva yekushanda nguva dzose: kupfuura maawa mana
● Kudzivirirwa kwebhatiri: Kana yakaderera voltage yakayerwa, ndapota ichajai panguva.
Battery charger
● Rated voltage: 100-240V
●Kakawanda: 50/60Hz
● Kuchaja magetsi: 12V
● Kuchaja ikozvino: 0.5A
● Nguva inodiwa kuti uwane mari yakakwana: inenge maawa manomwe
● Kushanda tembiricha: 0-55℃