GDPD-313M Inotakurika Partial Discharge Detector

GDPD-313M Inotakurika Partial Discharge Detector

Tsanangudzo Pfupi

TEV uye nzira yeAE inobvumwa uye yakakodzera tekinoroji kuti ishandiswe painternet chikamu chekubuda pachena.


Product Detail

Product Tags

GDPD-313M Portable Partial Discharge Detector1
GDPD-313M Portable Partial Discharge Detector2
GDPD-313M Portable Partial Discharge Detector3

Yekunze inoshanduka sensor (yesarudzo)

GDPD-313M Portable Partial Discharge Detector4

Parabolic sensor (wave condenser, yesarudzo)

TEV uye nzira yeAE inobvumwa uye yakakodzera tekinoroji kuti ishandiswe painternet chikamu chekubuda pachena.

GDPD-313M inoshandisa tekinoroji yekuona tekinoroji (AE) uye TEV modhi, inogona kunyatso kuve nechokwadi chekunzwa kwechiratidzo mukukanganisa pane-saiti nharaunda.Yakakodzera kuona PD kukanganisa uye kutsvaga PD chiratidzo chekuchinja kabati nezvimwe.

Features

Yakavakwa-mukati ultrasonic sensor.kukanganisa kwemagetsi kunogadzira ultrasonic wave panzvimbo yekukanganisa, uye ultrasonic modhi inotumira iyo ultrasonic chiratidzo kuburikidza nenzeve kuti itarise nzvimbo kuti ione kubuda.Hunhu hwakasiyana-siyana hwekudedera, pop, uye hum hunogona kubatanidzwa nekukanganisa kwakasiyana.
Yakavakirwa-mukati-yakanyanya-chaiyo TEV sensor, yakasanganiswa nemagetsi masaini anogadzirwa nechikamu kuburitswa, kuona dzingangove dzemukati kubuda kutadza njodzi.
MuUltra Mode, iyo main interface inoratidza iyo partial discharge amplitude (dBuv), uye inoshandisa iyo yero, yegirinhi, uye tsvuku mavara kuwedzera kuoma kwechikamu chekubuda.Panguva imwecheteyo, iyo mahedhifoni ekuteerera vhoriyamu (Vol) inogona kugadziriswa.
Mune inotenderera redhiyo modhi (TEVMode),iyo huru interface inoratidzira chikamu chekuburitsa amplitude, huwandu hwemapulses, iyo yakazara nhamba yemapulses uye discharge intensity level mune yega yega frequency frequency kutenderera.
Powered by rechargeable lithium bhatiri, inoenderera ichishanda kweanopfuura maawa matanhatu.
Yechokwadi ruvara LCD kuratidza, chaiyo-nguva bhatiri simba kukurumidza;bhatani refirimu remuviri riri nyore kushandisa uye rakashongedzerwa nekunze kwepamusoro-kutendeseka ruzha kuderedza mahedhifoni.

Zvinotsanangurwa

TEV Sensor

Measurement range 0-60dB
Bandwidth 3-100MHz
Akururama ±1dB
Max.pulse times per cycle 1000
Min. pulse times 1

Ultrasonic sensor

Measurement range -7dB~60dB
Resolution 1dB
Akururama ±1dB
Skunzwa -65dB
Cpinda frequency 40.0±1.0KHz
Bandwidth 2.0KHz

Bhatiri

Built-in bhatiri Lithium bhatiri, 8.4V,1800mAh
Unazvo Kunenge 6hours
Charyaenda nguva Aanenge 5hours
Pkudzora Over-voltage uye over-current kuchengetedzwa

Charger

Rated voltage 8.4V
Output current 1A
Temperature 10 ℃-60 ℃
Humidity <80%

 Hardware

Sgehena

Monochrome kuumba plastiki

Stendai

240 * 320 TFTLCD skrini

Control

6 mabhatani

Iinterface

Micro USBiinterface,chiteshi chejaja, headphone port, chiteshi chekunze chekuunganidza wave muunganidzi

Headphone

High fidelity ruzha kudzima mahedhifoni

 Dimension

Size 178mmx75mm×30mm
Wsere 0.25KG
Case size 415mm×330mm×170mm
Casi uremu 2.3KG
Huremu hwese 2.7KG

Nzvimbo yekushanda

Ukana tembiricha -20 ℃ ~ 50 ℃
Environmental humidity 0-90%RH
IP kirasi 54

  • Zvakapfuura:
  • Zvinotevera:

  • Tumira meseji yako kwatiri:

    Nyora meseji yako pano uye utumire kwatiri

    Tumira meseji yako kwatiri:

    Nyora meseji yako pano uye utumire kwatiri