GDPD-414 Inotakurika Partial Discharge Detector

GDPD-414 Inotakurika Partial Discharge Detector

Tsanangudzo Pfupi

Iyo GDPD-414 Inotakurika Partial Discharge Detector inotora Smart Kurumidza kungwara simba bvunzo system, uye inotakurika yemunharaunda discharge yekuongorora chishandiso chekurarama chakakwira voltage insulation michina.

 

 

 


Product Detail

Product Tags

GDPD-414 Portable Partial Discharge Detector01
GDPD-414 Portable Partial Discharge Detector02
GDPD-414 Portable Partial Discharge Detector03

Main
unit

UHF sensor,
round type,yakakodzera GIS

UHF sensor, rectangle mhando, yakakodzera tambo yemagetsi, transformer, switchgear

GDPD-414 Portable Partial Discharge Detector04
GDPD-414 Portable Partial Discharge Detector05
GDPD-414 Portable Partial Discharge Detector06

HFCT, yakakodzera tambo yemagetsi, transformer

TEV sensor,
yakakodzera switchgear

Ultrasonic sensor, yakakodzera kushandura, switchgear

GDPD-414

Mifananidzo iri pamusoro ndeyokutanga kutaridza.

The GDPD-414 Portable (GDPD-414H handheld) Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684781 (14684481)).Iyo inogona kuchinjika kugadzirisa akasiyana masensa zvinoenderana neakasiyana zvigadzirwa kuti zviedzwe.TEV, ultrasonic uye HFCT inokodzera kuburitswa kwechikamu chekuonekwa kwe-high-voltage switchgear uye mhete network kabati;Ultrasonic uye UHF yakakodzera kuona GIS;Ultrasonic uye HFCT yakakodzera kuyedza tambo yemagetsi.Iyo yakavakirwa-mukati nyanzvi yekuongorora system inogona kuongorora iyo bvunzo data uye kutonga kuburitsa simba uye zvinokwanisika zvikamu.Inoshandiswa zvakanyanya mumagetsi emagetsi uye njanji.

GDPD-414 Portable Partial Discharge Detector07

Ultrasonic uye TEV sensor (2-in-1)

Features

Gamuchira yakakwira-kumhanya DSP/FPGA sampling board, 4-chiteshi synchronous data kutora.
Software system: yekuongorora software yakavakirwa paArM yakamisikidzwa system
6/8/16 chiteshi chinogona kugadzirwa
8.1 inch piritsi kana Thinkpad notebook sezvisarudzo
6/8/16 chiteshi chinogona kugadzirwa zvinoenderana nezvinodiwa nemutengi zvakasiyana.
Inogona kuratidza iyo PRPS uye PRPD mepu, ellipse dhayagiramu, discharge rate mepu, QT mepu, NT mepu, PRPD akawedzera mepu, fai-QN mamepu ega ega chiratidzo chiteshi.
 Matatu-mavara ekuratidza modhi yetsvuku, yero uye yebhuruu inoratidza kuoma kwechikamu chekubuda.

 

Mutengi anogona kusarudza ma sensors zvinoenderana neakasiyana akaedzwa zvinhu:

Sensors

TEV/AE/HFCT

AE/UHF

AE/HFCT

 

Zvakaedzwa Zvinhu

HV Swichgear uye Ring network kabati

 

GIS

 

Cable

 

 

GDPD-414 / GDPD-414H Zvinyorwa
PD chiratidzo chekutora host
CPU Kushanda frequency 1.2GHz / 800MHz
Operating system Linx yakamisikidzwa inoshanda sisitimu
Wired network port LAN network port
Wireless network port Yakavakwa-mukati isina waya WiFi (inosarudza)
System inomhanya ndangariro 1G / 512M
Sistimu yekuchengetedza ndangariro 512M / 256M
Dhata yekutora frequency 250MHz / 80MHz
Ultrasonic yekuona chiteshi
Chiyero chiyero 0-60mV
Frequency yekuona huwandu 20 ~ 200kHz
UHF yekuona chiteshi
Detection frequency 300 ~ 1800MHz / 300 ~ 1500MHz
Chiyero chiyero -80~10dBm
Error ±1dBm
Resolution 1dBm
HFCT yekuona chiteshi
Frequency range 0.5 ~ 100MHz
Error ±1dB
Dynamic Range 60dB
Chiyero chiyero 0-100mV
Kururama 1dB
TEV yekuona chiteshi
Frequency range 3 ~ 100MHz
Error ± 1dB / mV
Sensitivity 0.01mV
Chiyero chiyero 0-60dB / mV
Resolution 1dBm / mV
Bhatiri
Yakavakwa-mukati bhatiri Lithium bhatiri, 12V, 4400mAh / Lithium bhatiri, 12V, 2000mAh
Shandisa nguva anenge 8 maawa / anenge 6 maawa
Kuchaja nguva Anenge maawa maviri
Kudzivirirwa kwebhatiri Over-voltage uye over-current protection
Kuchaja bhatiri
Rated voltage 12.6V
Kuchaja yabuda ikozvino 2A
Kushanda tembiricha -20 ℃-60 ℃
Kushanda humidity <80%
GDPD-414H Handheld display terminal (giredhi remaindasitiri)
CPU Intel Quad Core Atom Z3735F
GPU Intel HD Graphic (Gen7)
Flash 32GB
RAM 2GB
Operating system Windows10
Display 8.1 inch 1280×800 IPS sikirini
Network interface Wifi uye Bluetooth
Bhatiri 3.7V 8500mAH polymer lithium ion bhatiri
Thinkpad Laptop kana Tablet PC
Size
Accessory kesi saizi / PD yekuwana saizi yekutambira 395mm*295mm*105mm / 240mm*165mm*55mm
PD host uremu 3kg / 0.65kg
PD hose kesi saizi / Ratidza piritsi terminal saizi 570mm*360mm*240mm / 395mm*295mm*105mm
Ratidza tablet terminal uremu 0.85kg
Saizi yebhokisi rese 570mm*360mm*240mm
Nzvimbo yekushanda
Kushanda tembiricha -20 ℃ ~ 50 ℃
Environment humidity 0 ~ 90% RH
IP level 54

GDPD-414H Handheld Partial Discharge Detector

GDPD-414H-Handheld-Partial-Discharge-Detector1
GDPD-414H-Handheld-Partial-Discharge-Detector01
GDPD-414H-Handheld-Partial-Discharge-Detector
GDPD-414H-Handheld-Partial-Discharge-Detector2
GDPD-414H Handheld Partial Discharge Detector5
GDPD-414H Handheld Partial Discharge Detector4

  • Zvakapfuura:
  • Zvinotevera:

  • Tumira meseji yako kwatiri:

    Nyora meseji yako pano uye utumire kwatiri

    Tumira meseji yako kwatiri:

    Nyora meseji yako pano uye utumire kwatiri