GDBT-1000kVA Transformer Test Bhenji
GDBT Transformer Test System inogona kuitisa bvunzo dzese dzekuchinja, kusanganisira Kwete-mutoro uye mutoro bvunzo, Induced voltage bvunzo, Simba frequency inomira voltage bvunzo, chikamu discharge bvunzo, DC kuramba bvunzo, inotendeuka chiyero bvunzo, tembiricha inokwira bvunzo nezvimwe.
-
GDB-P Auto Transformer Inoshandura Ratio Tester
Zvinoenderana neIEC uye neakakodzera nyika zviyero, transformer inotendeuka chiyero bvunzo ipurojekiti inodiwa mukugadzirwa kwesimba rekushandura, kupihwa kwemushandisi uye bvunzo yekugadzirisa.
-
GDRB-B Transformer Frequency Response Analyzer
Power transformer winding deformation tester (frequency response method) inobva pachiyero chemaitiro emagetsi ekushandura mukati memhepo, inotora nzira yemukati yekukanganisa frequency response (FRA), inogona kutonga zvakarurama kukanganisa kwemukati kwevashanduri.
-
GDRB-C Power Transformer Winding Deformation Tester
Power transformer winding deformation tester (frequency response method) inobva pachiyero chemaitiro emagetsi ekushandura mukati memhepo, inotora nzira yemukati yekukanganisa frequency response (FRA), inogona kutonga zvakarurama kukanganisa kwemukati kwevashanduri.
-
GDRB-F Transformer Winding Deformation Tester (SFRA & Impedance Method)
GDRB-F Transformer winding deformation tester inotora sweep frequency response analysis (SFRA) nzira uye impedance nzira yekuona mafambiro ekushandura mhepo uye kutadza kwemakanika nekuda kwekuvhunduka kwemuchina, chekufambisa kana mapfupi maseketi, ane maficha ekukurumidza bvunzo kumhanya, kugadzikana kwakanyanya uye ongororo ine simba. software.
-
GDB-D Transformer Turn Ratio Tester
GDB-D Transformer turn ratio tester yakagadzirirwa nhanho nhatu shanduko musimba system uye kunyanya yeZ mhando inomonereka transformer uye mamwe ma transformer ane yakakura isina-mutoro ikozvino.
-
GDBR-P Transformer Mutoro, Hapana-mutoro uye Capacity Tester
Kuyera transformer Kwete-mutoro ikozvino, Hapana-mutoro kurasikirwa, pfupi redunhu voltage, kupfupika kwedunhu kurasikirwa uye kugona.
Nzira dzekuedza mamita matatu. -
GDB-H Handheld Automatic Transformer Inoshandura Ratio Tester
Inogona kunyatso kuyera kutendeuka kwereshiyo, boka uye chikamu chekona, iyo inokodzera marudzi ese eshanduko akadai seZ type transformers, rectifier transformers, magetsi echoto chemagetsi, phase-shifting transformers, traction transformers, scott uye invert-scott transformers.
-
GD6800 Capacitance uye Dissipation Factor Tester
GD6800 isa zvizere otomatiki 10kV insulation simba factor/dissipation factor (tan∂) bvunzoeryakagadzirirwa kuongororwa kwemamiriro ekudzivirira kwemagetsi mune yakakwira voltage midziyo yakadai sema transformer, bushings, circuit breaker, tambo, zvinosunga mheni nemichina inotenderera.
-
GDOT-3B 100kV 3 Makapu Insulation Oiri Kuputsa Voltage (BDV)Tester
GDOT-3B 100kV 3 Makapu Insulation Oiri Kuputsa Voltage Tester iGDOT-3B inotora imwe-chip microcomputer seyakakosha, inoziva ese ma test automation, chiyero chechiyero chepamusoro, inovandudza zvakanyanya kushanda zvakanaka, uye zvakare inoderedza zvakanyanya kusimba kwevashandi. .
-
GDB-IV Three Phase Transformer Inoshandura Ratio Tester
Iyo yemukati simba module muyedzo inogadzira iyo matatu-phase simba kana maviri-chikamu simba, iyo inobuda kune yakakwira voltage divi retransformer.Ipapo iyo yakakwira voltage uye yakaderera voltage inotorwa panguva imwe chete.Pakupedzisira, boka, reshiyo,kukanganisa,uye mutsauko wechikamu unoverengerwa.
-
GD6900 Capacitance uye Dissipation Factor Tester
GD6900 inoyera capacitance uye dielectric kurasikirwa factor (tgδ) yemhando yepamusoro yemagetsi emagetsi.Iyo yakabatanidzwa chimiro, yakavakirwa-mukati dielectric kurasikirwa bvunzo bhiriji, inoshanduka frequency inogadziriswa magetsi, inosimudzira transformer uye SF6 yakajairwa capacitor.