AC High Voltage Test Sets yeGIS

Tsanangudzo Pfupi

AC Resonant Test System ye Substation Magetsi Equipment, inonyanya kuumbwa nekusiyana frequency magetsi emagetsi, Excitation Transformers, Reactors, Capacitive dividers, iyo yakagadzirirwa AC kushingirira bvunzo yemagetsi emagetsi emagetsi pa500kV kana pazasi.

 


Product Detail

Product Tags

Applications

Transformer
GIS system
SF6 switchgear
Cables
Bushing
Insulator
CT/PT
Mamwe macapacitive midziyo

Features

Tembiricha diki inokwira pamutoro wakayerwa.Dry kana Oiri mhando reactor, yakakwira mechanic simba, yakanaka insulation, yakanaka uye yakavimbika.
Inogadziriswa simba re frequency control source.Kudzivirirwa kwakasimba, kugadzikana kwakanaka.Nemaitiro akawanda ekushanda, ari nyore kushanda.
Iine 220V kana 380V single phase simba, yakanakira pane-saiti magetsi sourcing.
Flexible configuration.Different mhando reactors zvokusarudza, kusangana akasiyana bvunzo chinhu zvinodiwa.Multifunctional, inodhura.

Zvinotsanangurwa

Yakayerwa yakabuda voltage: zvichibva pane zvakasiyana bvunzo zvinhu.
Kubuda kakawanda: 20- 300Hz.
Waveform: yakachena sine wave, THD <1.0%.
Max.simba: 1000kVA uye pasi.
Duty Cycle: Kuenderera mberi kushanda nguva 15mins imwe nguva pakuzara kwemagetsi kubuda.(kana zvinodiwa nevatengi.)
Frequency kugadzirisa senitivity: 0.1Hz, kusagadzikana <0.05%.
Simba rekupa: 380/220V ± 15%/50Hz ± 5%.

Product Configuration

GDTF-108/108

Input voltage (V)

380

Kubuda kwemagetsi (kV)

0-108

Kugona (kVA)

108

Application scope

31500kVA kana pasi

35kV simba rekushandura

35kV circuit breaker uye bhazi bar, insulators

10kV (300 mm²) tambo 2000m

35k V (300 mm²) tambo 500m

Main configurations

5kW Variable frequency source 1 set

5kVA Inonakidza transformer 1 set

Reactor 27kV/1A 4sets

Capacitive divider 100kV

GDTF-216/216

Input voltage (V)

380

Kubuda kwemagetsi (kV)

0-216

Kugona (kVA)

216

Application scope

110kV Circuit breaker uye bhawa rebhazi

110kV GIS

35kV(300 mm²) tambo 1500m

10kV(300 mm²) tambo 3km

110kV yakazara insulation Transformer

Main configurations

10kW Variable frequency source 1 set

10kVA Inonakidza transformer 1 set

Reactor 54kV/1A 4sets

Capacitive divider 200kV

GDTF-270/270

Input voltage (V)

380

Kubuda kwemagetsi (kV)

0-270

Kugona (kVA)

270

Application scope

110kV GIS uye transformer

110kV GIS uye transformer

35kV (300 mm²) tambo 2km

Main configurations

15kW Variable frequency source 1 set

15kVA Inonakidza transformer 1 set

Reactor 54kV/1A 5sets

Capacitive divider 300kV

GDTF-400/400

Input voltage (V)

380

Kubuda kwemagetsi (kV)

0-400

Kugona (kVA)

400

Application scope

220kV GIS uye transformer

10kV (300 mm²) tambo 4km

35kV (300 mm²) tambo 1km

Main configurations

20kW Variable frequency source 1 set

20kVA Inonakidza transformer 1 set

Reactor
100kV/1 A 4sets

Capacitive divider 400kV

GDTF-520/260

Input voltage (V)

380

Kubuda kwemagetsi (kV)

0-260

Kugona (kVA)

520

Application scope

110KV Circuit breaker uye bhawa rebhazi

110kV GIS

110kV (300 mm²) tambo 800m

35kv (300 mm²) tambo 3km

10kV (300 mm²) tambo 6km

110kv yakazara insulation Transformer

Main configurations

25kW Variable frequency source 1 set

25kVA Inonakidza transformer 1 set

Reactor 65kV/2A 4sets

Capacitive divider 300kV

GDTF-500/500

Input voltage (V)

380

Kubuda kwemagetsi (kV)

0-500

Kugona (kVA)

500

Application scope

220kV kana pasi peCT/PT

220kV kana pasi pemakwenzi

220kV kana pazasi MaInsulators, zvinodimbura

220kV kana pazasi Circuit breaker

220kV kana pasi peIsulation Instrument

Main configurations

20kW Variable frequency source 1 set

20kVA Inonakidza transformer 1 set

Reactor 125kV/1A 4sets

Capacitive divider 500kV

GDTF-600/600

Input voltage (V)

380

Kubuda kwemagetsi (kV)

0-600

Kugona (kVA)

600

Application scope

110kV (300 mm²) tambo 800m

35kv (300 mm²) tambo 110m

35-220kV GIS, transformers, insulators

Main configurations

30kW Variable frequency source 1 set

30kVA Inonakidza transformer 1 set

Reactor 120kV/1A 5sets

Capacitive divider 600kV

GDTF-800/800

Input voltage (V)

380

Kubuda kwemagetsi (kV)

0-800

Kugona (kVA)

800

Application scope

110kV (300 mm²) tambo 800m

220kv (300 mm²) tambo 500m

35-500kV GIS, transformers, insulators

Main configurations

40kW Variable frequency source 1 set

40kVA Inonakidza transformer 1 set

Reactor 200kV/1A 4sets

Capacitive divider 800kV