GD3128 Series Insulation Resistance Tester
GD3128 yakatevedzana Insulation Resistance Tester ine yakakwana yekuyedza basa reakasiyana-siyana ekudzivirira maparamendi uye yakanakisa anti-kupindira kugona, iyo inogona kushandiswa kuyedza kudzivirira kwekudzivirira kwehukuru hukuru hwemagetsi emagetsi emagetsi uye mitsara yekufambisa munzvimbo yakasimba inductive senge substation.Iyo chiridzwa inotora yechokwadi color touch screen, data rese rekuyedza uye simba rebhatiri rinoratidzwa pachiratidziro chimwechete nekungotarisa, uye kusanganiswa kweknob switch uye kiyi kunoita kuti mashandiro acho ave nyore.Mushandisi haadi kubata nemusoro nzira yekushandisa.Dzvanya "BATSIRA" pachiratidziro kuti ubudise nzira yekushandisa, iyo inogona kunyatso kutungamira mushandisi kushandisa chiridzwa.Iyo chiridzwa ine basa rekukurumidza kuburitsa, iyo inogona kuburitsa voltage yechinhu chakaedzwa ipapo pasina kuwedzera discharge circuit.Iyo voltage yekutarisa yechiridzwa inogona kungotarisa iyo mhenyu voltage yechinhu chakaedzwa.Kana iyo voltage ichipfuura 36V, bvunzo inozorambidzwa otomatiki, iyo inogona kunyatso chengetedza chiridzwa nevashandisi.
Iyo chiridzwa inotora yakakura rechargeable lithium bhatiri pack.Iyo yekuyedza timer yechiridzwa inorekodha nguva yekuyedza uye inochengeta mhinduro ine zuva nenguva.Iyo yekubata skrini inogona nyore kuwana yakanyorwa nhoroondo data.Iyo yakasarudzika yakasarudzika USB interface inogona kurodha zvakachengeteka data rekuyedza kuPC.Chiridzwa chacho chine tambo yekuyedza ine yakapetwa kaviri insulation uye yekudzivirira layer, uye iyo yakakwira voltage bar ine inotsiva alligator clip uye hoko, iyo inogona kuchinjika kune dzakasiyana nzvimbo dzekuyedza.Iyo chiridzwa inotora yakasimba kaviri-layer shell chimiro, uye giredhi rekudzivirira rekunze bhokisi IP65, iyo inogona kudzivirira kupinda kwehunyoro uye guruva panguva yekufambisa uye kuchengetedza, uye zvino chengetedza chiridzwa kubva pakubonderana.
GD3128 nhevedzano ine hupamhi hwakasiyana, yakakwirira resolution, mashandiro ari nyore, kusimba uye kusimba, kurongeka uye kuvimbika, kuita kwakagadzikana, uye kugona kwakasimba kwekurwisa kupindira.Chiridzwa chine insulation kuramba bvunzo (IR);polarization index test (PI);absorption ratio test (DAR);ramp test (RAMP);sefa bvunzo (FR, 10S, 20S, 30S, 40S mana sarudzo);voltage test (V);Capacitance test (uF);ikozvino bvunzo (nA) uye mamwe mabasa.Chiridzwa chacho chakakodzera bvunzo yekudzivirira kudzivirira yemidziyo yemagetsi, mitsara yekufambisa uye zvimwe midziyo mikuru pasi penzvimbo yehukuru hukuru, yakakwira voltage uye induction yakasimba.Icho chinowanzoshandiswa uye chakakosha chiridzwa chemagetsi emagetsi, nharembozha, meteorology, komputa kamuri, oiri munda, electromechanical kuisirwa uye kugadzirisa, uye magetsi ekupa madhipatimendi emaindasitiri nemabhizinesi emigodhi.
●Iyo yakanyanya kupfupi-yedunhu ikozvino 7mA.
●Insulation resistance test (IR), polarization index test (PI), absorption ratio bvunzo (DAR).
●Ramp bvunzo modhi (RAMP), sefa bvunzo modhi (FR), capacitance bvunzo (uF)
●Voltage yekutarisa basa, otomatiki tarisa iyo yakachajwa voltage yechinhu chakaedzwa.
●Yedza timer basa, rekodha otomatiki nguva yekuyedza.
●Otomatiki discharge basa, otomatiki uye nekukurumidza kuburitsa kubhadharisa kwechinhu chekuyedza mushure mekuyedzwa, pasina yekunze discharge circuit.
●Automatic shutdown basa.
●Hombe yekubata ruvara skrini.
●Kaviri-layer shell chimiro, yakasimba uye yakasimba, yekudzivirira giredhi IP65.
●High-capacity rechargeable lithium bhatiri pack.
●Basa rekuchengetedza, rinogona kuchengetedza otomatiki mapoka zana echokwadi-nguva bvunzo data ine bvunzo zuva uye nguva uye bvunzo nguva.
●Kurodha basa, rakashongedzerwa ne USB interface, rekodhi data rinogona kurodha kumakomputa kuti riongorore nhamba yedata.
Product Model | Rated Voltage | Insulation Resistance Range | Short Circuit Current |
GD3128A | 250V,500V,1kV,2.5kV,5kV | 0.50MΩ~10.0TΩ | ≥7mA |
GD3128B | 250V,500V,1kV,2.5kV,5kV,10kV | 0.50MΩ~20.0TΩ | ≥7mA |
GD3128C | 250V,500V,1kV,2.5kV,5kV,10kV,15kV | 0.50MΩ~30.0TΩ | ≥7mA |
Insulation Resistance Range uye Kururama
Rated Voltage | Insulation Resistance Rage | Kururama | Remark |
250V | 0.50MΩ~50.0GΩ | ±5%rdg±3dgt |
|
50.0GΩ~500GΩ | ±20%rdg±3dgt |
| |
500V | 1.00MΩ~100GΩ | ±5%rdg±3dgt |
|
100GΩ~1.00TΩ | ±20%rdg±3dgt |
| |
1000V | 1.00MΩ~200GΩ | ±5%rdg±3dgt |
|
200GΩ~2.00TΩ | ±20%rdg±3dgt |
| |
2500V | 1.00MΩ~500GΩ | ±5%rdg±3dgt |
|
500GΩ~3.00TΩ | ±20%rdg±3dgt |
| |
5000V | 1.00MΩ~1.00TΩ | ±5%rdg±3dgt |
|
1.00TΩ~10.0TΩ | ±20%rdg±3dgt |
| |
10KV | 1.00MΩ~2.00TΩ | ±5%rdg±3dgt |
|
2.00TΩ~20.0TΩ | ±20%rdg±3dgt |
| |
15KV | 1.00MΩ~3.00TΩ | ±5%rdg±3dgt |
|
3.00TΩ~30.0TΩ | ±20%rdg±3dgt |
1 TΩ (Tera ohm)=1000GΩ=1012Ω
1 GΩ (Giga ohm)=1000MΩ=109Ω
1 MΩ (Mega ohm)=1000KΩ=106Ω
Function | Insulation resistance measure (IR);polarization index kuyerwa (PI);absorption ratio (DAR);ramp test mode (RAMP);sefabasa(10S, 20S, 30S, 40S);vkuyera kwemafuta (V);capacitancekuyerwa(uF);kuyerwa kwazvino(nA) |
Magetsi | Rechargeable lithium bhatiri 6.2Ah |
Rated Voltage | GD3128A: 250V, 500V, 1kV, 2.5kV, 5kV GD3128B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV GD3128C: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV, 15kV |
Output Voltage Accuracy | (5%~10%) ±10V |
Insulation Resistance Test Range | GD3128: 0.50MΩ~10.0TΩ GD3128B: 0.50MΩ~20.0TΩ GD3128C: 0.50MΩ~30.0TΩ |
Output Short Circuit Current | ≥7mA |
Polarization Index Test | Ehe |
Absorption Ratio Test | Ehe |
Ramp Test Mode | Edzai mumatanho e10% eiyo preset voltage kusvika preset voltage. |
Sefa Test Mode | 10S, 20S, 30S, 40S ina sarudzo. |
Voltage Test | Range: AC/DC: 0V~1000V; Kunyatsoita: ± 5%rdg±3V |
Capacitance Test | Range: 10nF~25uF; Kunyatsoita: ±10%rdg±10nF |
Current Test | Range: 0.01nA~7mA; Kunyatsoita: ±5%rdg±0.5nA |
Voltage Monitor | Monitor voltage yetested chinhu, uye tarisa mamiriro ekubuda mushure mebvunzo, inorambidzwa kuyedza kana voltage yadarika 36V, chengetedza chiridzwa uye mushandisi. |
Test Timer | Otomatiki rekodhi bvunzo nguva, nguvaingmhando: 0s ~ 9999s |
Kuchengeta Basa | Chengetedza otomatiki data reyedzo ine zuva rekuyedza uye nguva, yakazara yemapoka 1000 |
Upload Basa | Isa data rakachengetwa pakombuta uchishandisa USB yekutaurirana tambo. |
Battery Power Display | Nebhatiri simba rekuratidzira, kana bhatiri voltage yadzikira inoyeuchidza kutichargebhatiri. |
Automatic Shutdown | Mushure memaminitsi gumi nemashanu kutanga kuchadzima otomatiki pasina kana oparesheni. |
Dimension | 280mm×260mm×160mm |
Kurema | 4900g (kusanganisira bhatiri) |
Test Waya | Ruvara dzvuku high voltage test waya 1pc (inea alligator clip uye hoko), girini ruvara rwekuyedza waya 1pc, black color test wire 1pc |
Dziviriro Level | Vhara iyo kesi IP65, vhura iyo kesi IP40 |
Nzvimbo Yekushanda | -20 ℃~50 ℃; 80% rh |
Store Environment | -25 ℃~65℃; 80% rh |
Insulation Resistance | 50MΩ(1000V) (pakati pe test circuit uye shell) |
Kushingirira Voltage | AC 3kV50Hz 1 min(pakati pe test circuit uye shell) |
Safety | IEC61010-1, IEC61326-1 |