GDHX-9700 Phase Detector
GDHX-9700 Phase Detector inonyanya kushandiswa mumagetsi emagetsi tambo, nhanho, uye nhanho kutevedzana calibration mune substation, ine mabasa makuru anosanganisira kuongorora magetsi, chikamu calibration uye chikamu kutevedzana kuyerwa.Iyo inoshandisa kaviri kudzivirira uye mhando-nyowani dhijitari maseketi, ane akasimba ekurwisa-kupindira, anoenderana neEMC mazinga, akakodzera akasiyana emagetsi kukanganiswa mamiriro.
Iyo yakakwira voltage chikamu chiratidzo cheyero yakayerwa ichafambiswa zvakananga mushure mekurapwa, iyo handset inogashira nekuita chikamu chekuenzanisa, tarisa mhedzisiro mushure mekuonekwa kwechikamu, chaiyo-nguva yekuratidzira chikamu chekona musiyano uye vector.Inoshandisa tekinoroji yekutumira isina waya, yakachengeteka uye yakavimbika, inokurumidza, uye yakarurama, yakakodzera kushandiswa pamazinga akasiyana emagetsi (10V-500KV).Paunenge uchitarisa chimiro chegridi, inogona kunyatsoona chikamu chehukama hweakasiyana anotungamira kune matatu-chikamu chakabatana mutsara, pasina chero magetsi ekubatanidza pakati pezvikamu zviviri zvekuyerwa, izvo zvinoita kuti mashandisirwo echiyero chigadziriswe zvakanyanya uye chakachengeteka.
●Voltage renji: 10V ~ 500KV, inoshanda kune akasiyana voltage mamakisi.
●Kururama: kureba kwenguva pfupi: kukanganisa ≤± 3 °;kureba: kukanganisa ≤± 3 °.
●Sampling rate: 10 nguva / yechipiri.
●Zuva uye nguva kuseta, zuva uye nguva kugadzirisa, zviri nyore kuti vashandisi vatarise, tarisa iyo nhoroondo data.
●Backlight setting: kazhinji yakabatidzwa, kazhinji yakavharwa, mushandisi-inotsanangurwa mukati me0 ~ 999s.
●Auto shut-down: never, user-defined within 0 ~ 999 maminetsi.
●Mu-chikamu: ≤20 ° (mushandisi-inotsanangurwa kana chikamu chikumbaridzo chiri mukati me0-90 °, default 20 °)
●Kunze-chikamu: > 20 ° (mushandisi-inotsanangurwa kana chikamu chikumbaridzo chiri mukati me0-90 °, default 20 °)
●Pa-saiti calibration basa: pa-saiti calibration inogona kuitwa pane yakaedzwa waya kuti ive nechokwadi chechokwadi chechikamu chekona.
●Multiple mode dhizaini, zvirinani kushanda, zvakachengeteka zvakanyanya, zviri nyore.
●Yakasarudzika yemunhu-muchina interface, nyore kushanda.
●FCC antenna dhizaini, chiratidzo chakasimba, nyore kupinda mumadziro, magonhi, uye zvipingamupinyi.
●Kudzivirira kaviri, anti-kupindira kwakasimba, mukutevedzera zvizere EMC zviyero.
●Machati uye data kuratidza, iri nyore kuverenga, ine zuva uye nguva yekuratidzira basa.
●Hunhu kuyerwa: kuratidzwa neacousto-optic chiratidzo.
●Quantitative kuyerwa: chaiyo-nguva kuratidzwa kwechikamu chekona musiyano, kukanganisa ≤5 °.
●Phase sequence check: positive phase sequence, negative phase sequence (120 °, 240 °).
●Pasi peGPS satellite nguva sevhisi, nhambwe yekuona pakati pe detector Xa neYa iri ≥500km.
●Data kuchengetedza huwandu hwe2000 mapoka.Inogona kubvunza uye kuwana kune nhoroondo data.
●Kureba kwetsvimbo yakajairwa yekuvharisa ndeye 4m, uye iyo inoshanda giredhi regiredhi resimbi yekudzivirira ndeye ≤ 220kV.
Voltage range | 10V ~ 500kV |
Magetsi | Huye-yakabatwa unit: yakakura simba lithium bhatiri |
Xa & Ya detector:AA saizi yealkaline bhatiri (1.5V) 3pcs | |
Wireless transmission | Kuona kureba 150m |
In-phase | ≤20 ° (mushandisi-inotsanangurwa kana chikamu chikumbaridzo chiri mukati me0-90 °) |
Kunze-chikamu | >20 ° (mushandisi-inotsanangurwa kana chikamu chikumbaridzo chiri mukati me0-90 °) |
Ratidza kururama | Quantitative kuyerwa ≤5° |
Kugadziriswa kwechikamu chekona | 1° |
Phase kutevedzana kuyerwa | Kutevedzana kwechikamu kunotarwa kuburikidza newachi 120°/ counterclockwise 240° |
Satellite timing range | 2 ~ 30 maminitsi |
Display | Positive type LCD screen, yakajeka muchiedza chezuva. |
Kushanda tembiricha | -35~+50℃ |
Kuchengetedza tembiricha | -40~+55 ℃ |
Hunyoro hwehukama | ≤95%RH, kuderedza |
Chikwata chakabatwa nemaoko | 0.31 kg |
Detector Xa | 0.16 kg |
Detector Ya | 0.16 kg |