GD3127 Series Yakakwira Voltage Insulation Resistance Tester
GD3127 Series Insulation Resistance Tester inoshandiswa zvakanyanya mukuchengetedza midziyo yemagetsi mu transformer substation, magetsi plant, etc. Yakakodzera kuita chiyero chekudzivirira kwekudzivirira (IR), polarization index (PI), absorption ratio (DAR), ramp ( RAMP), sefa (FR, 10s, 20s, 30s, 40s 4 sarudzo), voltage (V), ikozvino (nA) yemarudzi ese emhando yepamusoro yemidziyo yemagetsi, kusanganisira switchgear, transformers, reactors, capacitor, motors, jenareta uye tambo, etc.
GD3127 Series ndiyo yakakwana bvunzo chishandiso chekutanga kuzivikanwa uye kuwanikwa kwedziviriro kana kufanofungidzira kugadzirisa zvirongwa zvekutadza kutadza kwemidziyo.Izvo zvakakosha zvikuru kuve nechokwadi chemhando yechigadzirwa uye kuchengetedzwa kwevanhu nemidziyo iri kushanda.Kuita kwekudzivirira kwezvigadzirwa zvemagetsi ndechimwe chezviratidzo zvakakosha kuti uongorore mhando yekudzivirira, iyo inoratidzwa neiyo insulation yekudzivirira bvunzo.
●Max.pfupi ikozvino> 5mA.
●Insulation kuramba (IR), polarization index (PI), absorption ratio (DAR).
●Ramp (RAMP), sefa (FR), voltage (V).
●Chengetedza otomatiki mhenyu yemagetsi echinhu chakayerwa, uye wotorambidza bvunzo kana voltage ichipfuura 36V, iyo inodzivirira zvinobudirira chiridzwa uye anoshanda.
●Basa rekuita, otomatiki rekodha nguva yekuyedza.
●Bvisa otomatiki yakakwira voltage mushure mekuyerwa kwapera, nguva yekuburitsa haipfuuri masekonzi makumi matatu.
●Automatic simba off basa.
●Hombe LCD skrini dot matrix inoratidzira ine yakagadzikana kuita.
●Kaviri-layer shell chimiro, yakasimba uye yakasimba, yekudzivirira giredhi IP65.
●Huru huwandu hunodzokororwa lithium bhatiri paki.
●Basa rekuchengetedza, rinogona kuchengetedza otomatiki 1000 seti yechaiyo-nguva bvunzo data ine bvunzo zuva uye nguva uye bvunzo nguva.
●Kurodha basa, rakashongedzerwa ne USB interface, rekodhi data rinogona kurodha kumakomputa kuti riongorore nhamba yedata.
Function | Insulation resistance(IR), polarization index(PI), absorption ratio (DAR), ramp(RAMP), filter (FR, 10s, 20s, 30s, 40s 4 sarudzo), voltage(V), current (nA) |
Magetsi | Rechargeablelithium bhatiri5.2Ah |
Rated voltage | GD3127: 250V, 500V, 1kV, 2.5kV, 5kV GD3127B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV |
Kubuda kwemagetsi akururama | (5% -10%)±10V |
Insulation resistance kuyera range | GD3127:0.50MΩ~2.00TΩ GD3127B: 0.50MΩ~5.00TΩ |
Short circuit current | >5mA |
Polarization index(PI) | Ehe |
Absorption ratio (DAR) | Ehe |
Ramp (RAMP) bvunzo maitiro | Edzai mumatanho e10% eiyo preset voltage kusvika preset voltage |
Sefa test mode | Sarudzo ina dze10S, 20S, 30S, 40S |
Voltage test | Range: AC/DC 0V-1000V, kururama:±5%rdg±3V |
Muedzo wazvino | Range: 0.01nA-7mA, kunyatsoita:±5%rdg±0.5nA |
Voltage monitor | Tarisa magetsi echinhu chakayedzwa, tarisa mamiriro ekubuda mushure mebvunzo, uye rambidza bvunzo kana voltage yakakura kupfuura 36V, chengetedza chiridzwa uye anoshanda. |
Test timer | Rekodha otomatiki nguva yekuyedza, nguva yenguva: 0s~9999s |
Storage | Otomatiki chengetedzo yebvunzo data ine zuva uye nguva, inokwana 1000 mapoka |
Kukurukurirana | Isa iyo yakachengetwa bvunzo data pakombuta kuburikidza ne USB yekutaurirana tambo. |
Bhatiri | Pane bhatiri chiyero chinoratidza, chiyeuchidzo kubhadharisa nenguva iyo bhatiri voltage yakadzikira |
Auto power off basa | Auto power inodzima mushure memaminitsi gumi nemashanu |
Dziviriro kirasi | IP65/IP40 |
Insulation resistance | 50MΩ(1000V) (pakati pedunhu rekuyedza uye goko) |
Kushingirira voltage | AC 3kV 50Hz 1min (pakati petest circuit uye shell) |
Mitemo | IEC61010-1, IEC61326-1 |
Kushanda tembiricha uye mwando | - 20℃ ~ +50℃ <80%RH |
Kuchengetera tembiricha uye mwando | - 25℃ ~ +65℃80%RH |
Magetsi | 220V AC 50Hz |
Dimension (mm) | 280(L)*260(W)*160(H) |
Kurema | 4400g (kusanganisira bhatiri) |
Insulation resistance tester | 1 set |
High voltage test wire (Tsvuku) | 1 chidimbu |
Test waya(Girinhi) | 1 chidimbu |
Testwaya(Nhema) | 1 chidimbu |
Power adapter | 1 piece |
Mushandisi's gwara | 1 kopi |
Testreport | 1 kopi |