GD2000D Insulation Resistance Tester
GD2000D digitaalinen insulation resistance tester inogadzirwa nekambani yedu inoshandisa yakamisikidzwa indasitiri imwe chip chaiyo-nguva inoshanda sisitimu.Iyo yedhijitari analog pointer uye yedhijitari yemunda kodhi kodhi yakanyatsobatanidzwa.Iyi nhevedzano yemamita ine akasiyana emagetsi ekubuda mazinga (250V, 500V, 1000V, 2500V, 5000V, 10000V), hukuru hukuru, yakasimba anti-kupindira, analog pointer uye digital synchronous kuratidza, AC uye DC kaviri-kushandisa, nyore kushanda, otomatiki kukarukureta kweakasiyana ekuisa zviratidzi (absorption reshiyo, polarization index), mhedzisiro yekuyerwa kwakasiyana-siyana ine anti-simba-pasi basa, etc. Icho chakanakira bvunzo chiridzwa chekuyera kudzivirira kwekudzivirira kwemahombe-simba transformers, transformer, jenareta, yakakwirira- magetsi emagetsi, magetsi capacitor, tambo dzemagetsi, uye zvinosunga mheni.
DL/T 474-2006 "Guide for Insulation bvunzo pane saiti"
DL/T 845-2004 "Makakatanwa ekuyera ekupikisa michina"
DL/T 846-2004 "General tekinoroji yakatarwa yeakakwira voltage bvunzo michina"
DL/T 596-2005 "Yekudzivirira bvunzo kodhi yemagetsi magetsi emidziyo"
GB50150-2006 "Standard for hand-over test yemagetsi emagetsi midziyo yekuisa engineering"
GB/T16927.1 ~ 2-1997 "High voltage test techniques"
GB4793-1984 "Isulation co-ordination yeakakwira voltage kutapurirana uye kugovera michina"
1. Kubuda kwemagetsi (250V / 500V / 1000V / 2500V / 5000V) . Resistance range 0-200GΩ.
2. Mamodhi maviri anoratidza kudzivirira kwekudzivirira.
3. Auto-calculating absorption ratio uye polarization index.
4. Kushanda kwehushamwari, kuchengetedza kuchengetedza 19times kuyerwa kwemigumisiro.
5. Auto-discharge residual high voltage mushure mekuedzwa kwapera.
6. AC / DC magetsi emagetsi, ane bhatiri rechargeable kana AC adapter.
7. Kukwanisa kwakasimba kunopesana nekupindira, kuverenga kwakagadzikana uye kwakavimbika.
8. Portable design, yakakodzera basa remusango.
9. Short-circuit current ≥3mA, midziyo yakakodzera yekuedza kudzivirira kudzivirira kweshanduro huru, inductor, jenareta, HV motors, electric capacitor, cables uye surge arrester.
Chinhu Nha. | GD2000D | ||||||
Output voltage | 250V DC | 500V DC | 1000V DC | 2500V DC | 5000V DC | ||
Kururama | Tembiricha | 23℃±5℃ | |||||
Insulation resistance | 250-5G ±5% | 50-10G ±5% | 1M-20G ±5% | 2.5M-50G ±5% | 5M-100G ±5% | ||
Zvimwe zvakasiyana: ± 10% | |||||||
Output voltage | 2M-10G ±5% | 4M-20G ±5% | 8M-40G 0--+10% | 20-100GΩ 0 --+10% | 40-200G 0-- +10% | ||
Short-circuit current | ≥3mA | ||||||
Magetsi | 8*AA mhando yakakwira bhatiri rechargeable & yekunze adapta | ||||||
Working Temp.& Humidity | -10℃--40℃,max.relative humidity 85% | ||||||
Storage Temp.& Humidity | -20℃--60℃,max.relative humidity 90% | ||||||
Insulation | Max.2000MΩ kana voltage pakati pedunhu negoko iri 1000VDC. | ||||||
Kushingirira voltage | Kumira 1min kana voltage iri pakati pedunhu negoko3kV50Hz SineAC voltage | ||||||
Dimension | 230mm*190mm*90mm (L*W*H) | ||||||
Kurema | 3kg |
Insulation resistance tester | 1set |
Test waya | 1chidimbu |
Power adapter | 1chidimbu |
Tambo yemagetsi | 1chidimbu |
Bhuku reMushandisi | 1kopi |
Chitupa | 1kopi |