GD-2136H Cable Fault Locating System
GD2136H Cable Fault system chishandiso chakakosha kuchengetedza marudzi ese ematambo.Inoshandisa akasiyana nzira yekuona yekuyedza kukanganisa kwetambo, iyo inokodzera mazinga akasiyana voltage magetsi tambo uye tambo dzekutaura.
Iyo sisitimu ine pazasi mayunitsi:
1. GD-2131H Impulse Generator
2. GD-2132 Cable Fault Locator
3. GD-2133 Cable Fault Tester
4. Zvimwe zvinhu
GD-2131H Impulse Generator
Inoshandiswa kugadzira HV impulse kana uchishandisa impulse flashover nzira yekuona yakakwira impedance kukanganisa.
●Simba rekupisa kwakasimba, max.burning simba i1000W, nzvimbo yekuputsika inogona kupiswa munguva pfupi uye kushorwa kwekuputsika kunoderera.
●Kana ukashanda pamwe neGD-2133 Cable Fault Tester, pane nzira mbiri dzekutsvaga:
a.Low voltage pulse: Kana uchingoshandisa GD-2133, dunhu rakavhurika uye yakaderera impedance yekumisa kukanganisa kwetambo inogona kuwanikwa, uye kureba kwetambo kunogona kuyerwa kana wave kumhanya kwetambo kunogona kuonekwa.
b.Yakakwira voltage flashover: Iyo inoburitsa pulse voltage waveform yekukanganisa point inotorwa nekuburitsa sphere gap, iyo inogona kuwana kukanganisa kure.
●Gadzira mafungiro ezvakagadziriswa frequency.Kana ukashanda pamwe neGD-2132 Cable Fault Locator, pane zvinotevera mabasa:
a.Iyo nzira yekuteerera inoshandiswa kupedzisa iyo chaiyo nzvimbo yeyakajairwa yakakwirira-resistance uye flashover kukanganisa mapoinzi.
b.Kuti uone nzira yetambo, tsvaga tambo yakakosha.
c.Nekuputsika kwesimbi (yakafa pasi), uchishandisa magineti-munda kuyerwa kuwana nemazvo.
●Iyo zvakare inogona kushandiswa muDC HV inomira bvunzo.
●Simba rekuisa: AC 220V, 50Hz
●Output voltage: DC 0-32kV (inochinjika)
●Rated simba: 2000VA
●Max.energy: 2048J, 4uF
●DC flashover voltage: 32kV
●DC flashover ikozvino: 63mA
●Max.impulse ikozvino: 500mA
●Kuburitsa nzira: DC HV, imwe nguva, kutenderera
●Cycle kuburitsa nguva: 3-6 masekondi
●Environmental tembiricha:0-40 ℃
●Humidity: <75% RH
●Kureba: <1000m
●Insulation level: A
●Dimension: 430*540*410mm
●Kurema: anenge 31kg.
Kusanganisira transmitter, inogamuchira, Inductive probe, inogona kuonekwa mhandoframe.Yakakodzera kuyedza marudzi ese emagetsi tambo ine simbi conductor.
Basa rayo guru nderekutsvaga murombo wekudzivirira nzvimbo, kuona dunhu uyekudzika kwetambo yemagetsi.
●Kunzwa kwakanyanya
●Low static Drift
●High kururama kwenzvimbo
●Anti-kupindira
●LCD skrini kuratidza chiratidzo uye chimiro
●Yakavakwa-mukati rechargeable Li-bhatiri
●Kutsvaga nekutsvaga kure: yemunharaunda tambo 3km, imwe tambo inosvika makumi maviri
●Kuwana impedance range: 0-5MΩ.
●Kuwana kurongeka: ≤±10cm.
●Kuona tambo kudzika: <3m.
Inogona kuedza kukanganisa kwepamusoro-impedance flashover, yakakwirira-yakadereraresistance grounding, short-circuit, cable disconnection, kusabatana zvakanakakune ese marudzi etambo dzemagetsi (voltage degree 1kV-35kV),tambo yemunharaunda, tambo yekukurukurirana, coaxial-tambo uye simbi pamusoro pemutsetse.
Iyo zvakare inogona kuyera kureba kwetambo uye kuparadzira kumhanya kwemagetsi wave kumhanya patambo.
●Kuyedzwa kwakachengeteka, nekukurumidza uye kwakaringana.Inoshandisa LV impulse nzira uye HV flashover yekuona, iyo inoedza marudzi ese ekukanganisa kwetambo.Kunyanya kune flashover uye yakakwirira impendance kukanganisa kwetambo, inogona kuongororwa zvakananga pasina kupisa kuburikidza;kana yakashongedzwa neacoustic measurement locator, iyo chaiyo nzvimbo yekukanganisa inogona kunyatsotemwa.
●Kushandisa high speed data sampling tekinoroji.A/D sampling kumhanya ndeye 100Mhz, kuita kuti kuverenga kugadzirisa kwechiridzwa kuve 1m uye nzvimbo yekuona bofu i1m.
●Wave fomu uye data zvinoratidzwa otomatiki pane hombe yeLCD skrini.
●Wave fomu uye parameter kuchengetedza, rangarira basa.
●Basa rekuenzanisa kuyedza waveform yetambo kukanganisa neyakajairwa waveform.
●Wave form extending function.
●Ratidza zvakananga nzvimbo yekukanganisa uye yekuyedza nzvimbo yakananga kureba kana kuremerwa kure.
●Shandura kumhanya kwekuparadzira chero nguva zvichienderana neakasiyana tambo dzekuyedza.
●Yakavakwa-mukati rechargeable bhatiri.Diki size, inotakurika kutakura.
●Max.testing kureba: 15km(Vhura waya kusvika 100km).
●Kuonekwa kwemapofu: 1m
●Kugadziriswa: 1m
●Simba rekushandisa: 5VA
●Kupisa kwezvakatipoteredza: 0-40 ℃(muganho wekushisa: -10 ℃-50 ℃)
●Hunyoro hunyoro: 40℃(20℃90)%RH
●Atmospheric pressure: 86-106Kpa
●Saizi: 275 * 220 * 160mm
●Kurema: 1.8kg
Zvimwe zvishongedzo zvinosanganisira AF Stethoscope, Mahedhifoni, Grounding Pin, PD Locating Rack, RF Tracking Rod.