GDCF-900T Vehicle Mounted Cable Fault Locating System
Vehicle Mounted Cable Fault Locator system inoshandiswa kuCable Fault conditioning (kupisa-pasi), Pre-Location, Route Location, Pin-pointing & Testing yeHV & LV tambo dzemhando & saizi dzakasiyana.Iyo seti inokodzera kuita yakataurwa pamusoro-multifunction pamatambo emagetsi emhando dzakasiyana dzemagetsi kunyanya 33KV, 11KV, 415V uye tambo dzekudzora dzine giredhi 1.1 KV.Iyo seti ichashandiswa kumhando dzetambo dzinoti XLPE, PVC, PILC ine Al / Cu conductor.Tambo dzakaiswa pasi pevhu (pasi pevhu rakajeka, migero, kana RCC pamusoro, Horizontal Drilling muHDD Pipe), pamusoro pevhu kana chikamu pasi & chikamu pamusoro pevhu nehupamhi hwetambo kureba kutenderera 25Km.
Iyo cable fault locator inokodzera kukanganisa kutsvaga uye kunongedza anotevera marudzi ekukanganisa kwetambo.
●High resistance
●Kuramba kwakaderera
●Intermittent type inopenya kukanganisa.
●Sheath Fault nzvimbo
●Iyo sisitimu inoshandisa akawanda pulses (ARC reflection method), katatu pulses, impulse nzira, flashover nzira, TDR nzira yekuita hutsinye kuyerwa kwemarudzi ese ekukanganisa kwetambo.
●Inoshandisa acoustic magineti nzira yekuwana nemazvo nzvimbo dzekukanganisa.
●Inoshandisa electromagnetic induction musimboti kuteedzera isingazivikanwe tambo uye kutsvaga kudzika kwetambo.
●Ziva uye ubaye tambo dzeboka.
●Tsvaga uye uyere cable sheath.
Iyo mota yakashongedzerwa tambo yekutadza bvunzo system inoshandisa yakarongeka uye yemunhu yakazara dhizaini kuti iwane chikuru insulation kukanganisa kwe33KV, 11KV uye 415V tambo dzemagetsi, kutadza kuona nzvimbo yekunze sheath, chaiyo yekutemerwa poindi, nzira yekuyedza, chiziviso chehupenyu, kuchengetedza puncture. , DC kuramba kuti marudzi ese ezviridzwa zvekuyedza, magetsi ekugovera midziyo, zvishongedzo uye maturusi ebetsero anodiwa anoiswa pamotokari dzakagadziridzwa.
Yese bvunzo maitiro akachengeteka uye akavharwa, uye bvunzo mabasa akasiyana uye mhedzisiro yebvunzo ndeyechokwadi.
●Iyo mota ine zvikamu zvitatu: iyo cab, imba yekuvhiya uye imba yemidziyo.
●Iyo dhizaini yeoperation console inonzwisisika, uye tambo yekuvharisa bvunzo, kukanganisa pfuma kutonga, uye kukanganisa kureba kuyera kuyerwa kunogona kupedzwa zvachose mumotokari.
●Iyo fault test host inogona kupedzisa kuyerwa kwakashata kwetambo yekukanganisa point kureba uye inogona kusungirira otomatiki chinzvimbo.
●Imba yekudzora inogadzirwa neyakazvimiririra yakakwirira-yakawanda-yakakwirira-voltage chikamu, LCD inoratidza chaiyo-nguva ikozvino uye voltage, yakananga nehungwaru kupedzisa high-voltage kushanda uye kuburitsa.
●Cable chiziviso, nzira yekuyedza host yakanyudzwa mukamuri yekushandisa.
●Iyo tafura yekuvhiya inogadzirwa ne epoxy resin kuita iyo yese yakatsvinda uye yakanaka.Dhirowa rezvishandiso rakagadzirwa nekugadzirwa kwesimbi uye kuvharira njanji kukiya.Inogara kwenguva refu, isingatsvedzeri, haipfeki uye iri nyore kukwesha.Inochengetedza kuchengetedzwa kwemaitiro ekuedza.
Chimiro chemukati
1——Nzvimbo yekutyaira
2——Nzvimbo yokushanda
3——Center control unit
4——Kutadza kwechiratidzo kugadzirisa
5——Motokari yekuedza chiridzwa kabati
6—— High-voltage test unit
7——Chikwata chekudzivirira
8——Jenereta
9—— High Voltage Test cable reel
10——Ground cable reel
11——Rusvingo rwokuzviparadzanisa nevamwe
Iyo yose system inosanganisira
Item | Zita | Muenzaniso Nha. | Qty |
1 | Vehicle | -------------- | 1 |
2 | Multi-pulse cable fault tester | GD-4133 | 1 |
3 | Pulse coupler
| GD-4133S
| 1 |
4 | Canokwanisa kukanganisa nzvimbo
| GD-4132
| 1 |
5 | High voltage impulse jenareta | GD-2131H
| 1 |
6 | Cidentifier inokwanisa | GD-2134D
| 1 |
7 | Cinokwanisa puncture mudziyo | GD-2135B | 1 |
GD-2131H Impulse Generator
Inoshandiswa kugadzira HV impulse kana uchishandisa impulse flashover nzira yekuona yakakwira impedance kukanganisa.
●Kukwanisa kupisa kwakasimba, max.kupisa simba ndeye 1000W, nzvimbo yekuputsika inogona kupiswa munguva pfupi uye kuramba kwekuputsa nzvimbo kwakadzikira.
●Kana ukashanda pamwe neGD-4133 Cable Fault Tester, pane nzira mbiri dzekutsvaga:
a.Low voltage pulse: Kana uchingoshandisa GD-4133, dunhu rakavhurika uye yakaderera impedance yekumisa kukanganisa kwetambo inogona kuwanikwa, uye kureba kwetambo kunogona kuyerwa, kana wave kumhanya kwetambo kunogona kuonekwa.
b.Yakakwira voltage flashover: Iyo inoburitsa pulse voltage waveform yekukanganisa point inotorwa nekuburitsa sphere gap, iyo inogona kuwana kukanganisa kure.
●Gadzira mafungiro ezvakagadziriswa frequency.Kana ukashanda pamwe neGD-4132 Cable Fault Locator, pane zvinotevera mabasa:
a.Audio frequency: tsvaga yakakwira impedance, flash-over kukanganisa.
b.Kuti uone nzira yetambo, tsvaga tambo yakakosha.
c.To metallic breakdown (dead grounding), uchishandisa magineti-munda kuyerwa kuwana nemazvo.
●Iyo zvakare inogona kushandiswa muDC HV inomira bvunzo.
●Simba rekuisa: AC 220V, 50Hz
●Output voltage: DC 0-32kV (inochinjika)
●Rated simba: 2kVA
●Max.simba: 2048J, 4uF
●DC flashover voltage: 32kV
●DC flashover ikozvino: 63mA
●Max.simba rezvino: 500mA
●Kuburitsa nzira: DC HV, imwe nguva, kutenderera
●Cycle kuburitsa nguva: 3-6 masekondi
●Environmental tembiricha:0-40 ℃
●Humidity: <75% RH
●Kureba: <1000m
●Insulation level: A
●Dimension: 430*540*410mm
●Kurema: anenge 31kg.
GD-4132 Cable Fault Locator
Kusanganisira main unit, acoustic uye magineti sensor, anti-ruzha mahedhifoni uye charger.Yakakodzera kuyedza marudzi ese emagetsi tambo ine simbi conductor.Basa rayo guru nderekutsvaga kushomeka kwekudzivirira, kuona dunhu uye kudzika kwetambo yemagetsi.
●Acoustic Magnetic kugamuchira panguva imwe chete
●Simba rinopesana nekupindira kugona
●Iine anti-noise headphone.
●320 * 240 LCD skrini inoratidzaYakavakirwa-mukati hukuru hukuru Li-bhatiri, ine inokurumidza charger.
●Acoustic uye Magnetic chiratidzo waveform kuratidza, chiratidzo uye ruzha zviri nyore kusiyanisa.
●Uchishandisa chitubu kuyera acoustic uye magineti kunonoka, nyatso tarisa kukanganisa.Zvinoenderana nekutanga polarity yemagnetic waveform, inogona kuwana uye kuona nzira.
1. Kutsvaga basa
a.Acoustic chiratidzo chekufambisa bhendi: pakati frequency 400Hz, bandwidth 200Hz
b.Chiratidzo kuwana: 80dB
c.Kuwana kururama: 0.1m
2. Kugovera Simba a.Yakavakwa-muLi-bhatiri, nominal voltage 7.4V, kugona 3000mAH.b.Simba rekushandisa: 300mA, inoenderera yekushanda nguva 9hours.c.Chaja: inputAC220V±10%, 50Hz.Nominal kubuda 8.4V,DC 1A d.Kuchaja nguva: 4hours
3. Dimension: 270mm * 150mm * 210mm
4. Kurema: 1.5kg.
5. Shandisa mamiriro Tembiricha -10 ℃--40 ℃, humidity 5-90%RH, urefu <4500m
GD-4133 Cable Fault Detector
GD-4133 Cable Fault Detectot inoshandiswa kuyera kureba pakati pekukanganisa kwetambo.Zviri nyore kushandisa uye ine hushamwari interface.
Inogona kushandiswa yega pasi peyakaderera voltage pulse mode.Pasi pemamiriro ekuputika kwemazuva ano, inoda kushanda neGD-2131 high voltage generator.Pasi peyakawanda pulse mode, GD-4133S coupler inofanira kushandiswa pamwechete.Mushure mekutsvaga chinhambwe, GD-4132 fault locator inofanirwa kushandiswa kuratidza kukanganisa.Zvigadzirwa izvi zvinogona kusanganiswa kuita seti yekushanda kwepamusoro uye inovandudza tambo yekukanganisa system.
●7inch LCD skrini, inoshamwaridzana interface.
●Multiple distance yekutsvaga nzira:
Yakaderera voltage pulse nzira: inokodzera kuwanikwa kweiyo yakaderera kuramba kukanganisa, kupfupi dunhu kukanganisa, kuvhurika redunhu kukanganisa.Iyo zvakare inogona kushandiswa mukuyera kwehurefu hwetambo, majoini epakati, T majoini, uye tambo yekumisa kubatana.Iyi nzira zvakare inogona kushandiswa kugadzirisa wave velocity.
Pulse yazvino nzira: Inokodzera kuyera kureba kweiyo yakakwira kuramba kukanganisa, kukanganisa kukanganisa.Uchishandisa yazvino coupler kuunganidza zvikwangwani kubva pasi waya, zvinoita kuti mushandisi kure kure nepamusoro voltage.Iyi nzira yakachengeteka uye yakavimbika.
Multiple pulse: nzira yepamberi yekuyera chinhambwe.Iyo waveform iri nyore kuona uye iko kurongeka kwakakwira.
●200MHz chaiyo-nguva sampling.Max.0.4m kuyerwa kugadziriswa.Iyo ine diki yakafa zone uye yakakosha kune ipfupi tambo uye padyo nemhosva tambo.
●Bata skrini uye wodzvanya kiyi oparesheni
●PIP kopi (pic. kuchengetwa kwenguva pfupi)
●Pachave nehwindo guru uye matatu ekuchengetedza kwenguva pfupi windows anogona kutarisa matatu waveforms pamwechete.
●Yakavakwa-mukati yekushandisa system
Yakakosha software manejimendi yekusimudzira software, backup uye kudzoreredza.
●Scale basa
Nzvimbo yekutanga, 10 vanobatika, imwe tambo kukanganisa uye imwe yakazara hurefu inogona kuseta.
Ratidza chiyero uye yekuyedza waveform pamwe chete
●Waveform kuchengetedza uye kutaurirana nekombuta.
Kuchengetwa kwemukati kwemasaveforms.
Ne USB, kurodha kana kurodha data
Kukurukurirana nekombuta
●Kutarisira simba
Backlight inopera simba kana pasina kushanda mu2mins uye simba rinodzima mu10mins kana pasina kushanda.
Yakavakwa-muPolymer Lithium-ion bhatiri.
Nguva yekushanda inosvika maawa mashanu pakushandisa kwega kwega.
Mhosva yakasimba, iri nyore kutakura.
Nzira dzekuwana | Low voltage impulse nzira Impulse ikozvino nzira Multiple impulse method kana inoenderana neGD-4133S |
Max.Sampling frequency | 200MHz |
Gain range | 0-70dB |
Low voltage impulse voltage | 30V |
Max.resolution | 0.4m |
Max.Kutsvaga nzvimbo | 100km |
Dead zone | 2m |
Bhatiri | Nickel-metal hydride rechargeable mabhatiri, kutsungirira nguva kwemaawa mashanu |
Kukurukurirana interface | USB |
Magetsi | Input AC220V,50Hz,yazvino 2A,chaja kwemaawa masere |
Dim. | 274×218×81mm |
Kurema | 3.5kgs |
Operating Temperature | -10℃-40℃ |
Humidity | 5-90% RH |
Elevation | <4500m |
GD-4133S Multiple Pulse Coupler
Iri kushanda pamwe chete neGD-4133 Cable Fault Detector, inoshandiswa kuona yakakwira impedance leak kukanganisa, flashover fault, yakaderera impedance pasi uye yakavhurika yedunhu kukanganisa kwetambo dzemagetsi.GD-4133S yakapa pulse coupling siginecha yeGD-4133 uye yoitsaura kubva kune yakakwira voltage michina.
●Kushandisa tekinoroji yakasimukira yemapupu akawanda uye kuenzana kwepulse.
●Nekuchengetedzwa kweHV, dunhu rekuyeresa uye yakakwira voltage impulse simba inoparadzaniswa nemagetsi.
●Easy wiring, yakachengeteka uye yakavimbika.
Zvinotsanangurwa
●Pulse voltage: 300V (PP)
●Inobvumirwa kuisa impulse voltage: <35kV
●Inobvumirwa kupinza simba rekusimudzira: <2000J
●Simba rekuisa: 220VAC, 50Hz
●Dimension: 560 * 230 * 220mm
●Kurema: 7kg.
GD-2134D Cable Identifier
GD-2134D Cable Identifier inosanganisira transmitter uye inogamuchira, inogona kushandiswa kutsvaga uye kudzika kwetambo dzepasi pevhu nemapombi esimbi, zvakare kuona tambo kubva muboka retambo.
●Ratidza zvakananga nzvimbo yepombi.
●Kuruboshwe/Kurudyi museve chiratidzo cheCable Route Tracing.
●Nguva chaiyo yekuyera pombi ikozvino kutungamira uye yenhema / chaiyo kukurumidza pasi pechikamu frequency.
●Chakarurama/Nhema chiratidzo.Ichanongedza kumberi kana tambo yakaonekwa ichiteverwa nemazvo.Zvikasadaro, inonongedzera kumashure uye icharatidza "?".
●Kuyera otomatiki kwekudzika uye ikozvino.
●Cable identification: Clamp identification uye stethoscope identification.Kuzivikanwa kweClamp kunogona kuyera yazvino amplitude uye kutungamira kwetambo nemazvo uye kupa mhedzisiro chaiyo.Stethoscope identification inzira yechinyakare kana isiri nyore kushandisa Clamp identification.Iyo iri nyore wiring yeStethoscope kuzivikanwa.
●Kushandisa A rack(optional accessory) kutsvaga chikanganiso chekuisa insulation.Hazvidikanwi kugadzirisa kune zero nzvimbo.Museve unotaridza kwainobva pakanganisa.
●Yakazara digitalization yakakwira chaiyo sampling uye kugadzirisa, ine nhete yekugamuchira bhendi uye kupindira kwakasimba.Iyo inodzvanya zvizere ma frequency emagetsi uye kukanganiswa kweharmonic kubva kumatambo ari pedyo anomhanya.
●Active kuona uye kungoona chete.
●Yakavakwa-mukati yakakura simba Lithium bhatiri.Otomatiki magetsi-kudzima kana iri pasi-voltage kana pasina kushanda kwenguva yakareba.
Transmitter
●Kubuda (Matatu maitiro): Yakananga yekubatanidza kubuda, Clamp Coupling inobuda (yesarudzo), Radiation induction.
●Frequency (6 yesarudzo): 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz, kusanganisira 640Hz uye 1280Hz yakaoma frequency.Inogona kuona basa reChaiyo/Nhema chiratidzo uye pombi kuzivikanwa nerubatsiro rweReceiver.
●Mhosva yechiratidzo inoburitsa kuona Pipe yekumisa kukanganisa.
●Simba rinobuda: Max.10W, 10 matanho anogadziriswa.
●Output voltage yekubatanidza zvakananga: Max.150Vpp.
●Otomatiki impedance yekufananidza uye mabasa ekuremedza & pfupi-yedunhu kudzivirira.
●Simba rekushandisa: Internal rechargeable Lithium battery, 4pcs, model no.18650.zita 7.4V, 6.8Ah.
●Yakasimba uye inotakurika.
Receiver
●Input mode: yakavakirwa-mukati yekugamuchira coil, kugamuchira clamp (inosarudza), echometer (inosarudza), A rack (inosarudza).
●Mabhendi maviri ekuona ma frequency mabhendi: simba frequency uye radio frequency (RF).Hapana chikonzero chekubatanidza neodhiyo frequency jenareta.
●Kugamuchira frequency:
Active yekuona frequency: 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz
PF passive yekuona frequency: 50/60Hz uye 250/300Hz (mushandisi anogadziriswa)
RF passive yekuona frequency: pakati frequency ndeye 10kHz, 33kHz, 83kHz zvichiteerana.
●Detection mode: peak nzira, nhete nzira, null nzira.
●320 * 240 pixel LCD skrini.
●Yakavakwa-mukati Rechargeable lithium bhatiri, 2pcs 18650 Li bhatiri, nominal.7.4V, 3.4Ah.
●Yakasimba uye inotakurika.
Zvimwe zvinotsanangurwa
●Saizi: transformer 270 * 220 * 85mm, inogamuchira 700 * 270 * 120mm.
●Kurema: transmitter 2.2kg, inogamuchira 2.2kg.
●Chaja: inopinza AC 100-240V, 50/60Hz, inobuda DC 8.4V, 2A.
●Mamiriro ekushanda: Tembiricha -10--40 ℃.Humidity 5-90% RH, Altitude<4500m.
GD-2135 Cable Puncture Device
GD-2135B Cable Puncture Device zvakare tambo identifier, kuona tambo kubva muboka retambo.
Iyo isiri-yekubata yakachengeteka puncturing mudziyo, ine kure uye nguva yekudzora.
Chishandiso ichi chinosanganisira zvikamu zviviri, mudziyo wekuroverera zvipikiri uye mudziyo wekudzora.Iyo inofambiswa nebhatiri, iyo inoparadzanisa iyo puncture mudziyo kubva kune simba system, kuve nechokwadi chekuchengetedza magetsi.
●Inokodzera kubaya marudzi ese emagetsi tambo, yakachengeteka uye yakavimbika.
●Maitiro maviri ekushanda, kusanganisira kure uye nguva.Mabhatani maviri achashandiswa kupinda mukushanda mode, simbisa kuchengetedzwa kweanoshanda.
●Mabhatani maviri ari kure (kiyi C uye D yakadzvanywa panguva imwe chete).Kuti uve nechokwadi chekugamuchira kwakavimbika, iyo antenna yekutumira yeremote control inofanirwa kudhonzwa-kunze zvachose.
●Kushandisa pfuti mbiri kubaya nemakona maviri.Imwe bvunzo kushanda kupedzisa kaviri punctures.
●Iine ruzha alarm uye LCD kuratidza.
●Multiple dziviriro dhizaini nemakanika uye zvemagetsi.
●Yakakosha yakagadzirirwa tambo puncturing, yakanyatsogadziriswa pane tambo, yakaiswa chero kona.
●Kushandisa bhatiri powered, yakakodzera kushandiswa kwemusango pasina magetsi.Zvakare, inoparadzanisa iyo puncturing mudziyo kubva kune simba system, kuve nechokwadi chekuchengetedza.
●Wireless kure kure kure: ≤ 20M.
●Cable application: ese emagetsi tambo ≤ ¢125mm
●Simba rekushanda: 6pcs 1.5V bhatiri.
●Mamiriro ekushanda: tembiricha -10--50 ℃, humidityRH <95%.
●Kurema: 15kg kusanganisira aluminium kesi.
●Kuyera: 48 * 45 * 16cm