GD-4136H Cable Fault Locating System
GD4136H Cable Fault system chishandiso chakakosha kuchengetedza marudzi ese etambo.Inoshandisa akasiyana nzira yekuona yekuyedza kukanganisa kwetambo, iyo inokodzera mazinga akasiyana voltage magetsi tambo uye tambo dzekutaura.
Iyo sisitimu ine pazasi mayunitsi:
1.GD-2131H Impulse Generator
2.GD-4132 Cable Fault Locator
3.GD-4133 Multi-pulse Cable Fault Detector
4.GD-4133S Multi-pulse Coupler
5.Zvimwe zvishongedzo
GD-2131H Impulse Generator
Inoshandiswa kugadzira HV impulse kana uchishandisa impulse flashover nzira yekuona yakakwira impedance kukanganisa.
●Simba rekupisa kwakasimba, max.kupisa simba i1000W, kuputsikapoint inogona kupiswa munguva pfupi uye kuramba kwekuparara kwenzvimbo kwakadzikira.
●Kana ukashanda pamwe neGD-4133 Cable Fault Tester, pane nzira mbiri dzekutsvaga:
a.Low voltage pulse: Kana uchingoshandisa GD-4133, dunhu rakavhurika uye yakaderera impedance yekumisa kukanganisa kwetambo inogona kuwanikwa, uye kureba kwetambo kunogona kuyerwa kana wave kumhanya kwetambo kunogona kuonekwa.
b.Yakakwira voltage flashover: Iyo inoburitsa pulse voltage waveform yekukanganisa point inotorwa nekuburitsa sphere gap, iyo inogona kuwana kukanganisa kure.
●Gadzira mafungiro ezvakagadziriswa frequency.Kana ukashanda pamwe neGD-4132 Cable Fault Locator, pane zvinotevera mabasa:
a.Audio frequency: tsvaga yakakwira impedance, flash-pamusoro zvikanganiso.
b.Kuti uone nzira yetambo, tsvaga tambo yakakosha.
c.Kuputsika kwesimbi (yakafa pasi), uchishandisa magineti-munda kuyerwa kuwana nemazvo.
●Iyo zvakare inogona kushandiswa muDC HV inomira bvunzo.
●Simba rekuisa: AC 220V, 50Hz
●Output voltage: DC 0-32kV (inochinjika)
●Rated simba: 2kVA
●Max.energy: 2048J, 4uF
●DC flashover voltage: 32kV
●DC flashover ikozvino: 63mA
●Max.impulse ikozvino: 500mA
●Kuburitsa nzira: DC HV, imwe nguva, kutenderera
●Cycle kuburitsa nguva: 3-6 masekondi
●Environmental tembiricha:0-40 ℃
●Humidity: <75% RH
●Kureba: <1000m
●Insulation level: A
●Dimension: 430*540*410mm
●Kurema: anenge 31kg.
Kusanganisira main unit, acoustic uye magineti sensor, anti-ruzha mahedhifoni uye charger.
Yakakodzera kuyedza marudzi ese emagetsi tambo ine simbi conductor.
Basa rayo guru nderekutsvaga kushomeka kwekudzivirira, kuona dunhu uye kudzika kwetambo yemagetsi.
●Acoustic Magnetic kugamuchira panguva imwe chete.
●Simba rinopesana nekupindira kugona.
●Iine anti-noise headphone.
●320 * 240 LCD skrini inoratidza.
●Yakavakirwa-mukati hukuru hukuru Li-bhatiri, ine inokurumidza charger.
●Acoustic uye Magnetic chiratidzo waveform kuratidza, chiratidzo uye ruzha zviri nyore kusiyanisa.
●Uchishandisa chitubu kuyera acoustic uye magineti kunonoka, nyatso tarisa kukanganisa.
●Zvinoenderana nekutanga polarity yemagnetic.waveform, inogona kutsvaga uye kuona nzira.
1. Kutsvaga basa
a.Acoustic chiratidzo chekufambisa bhendi: pakati frequency 400Hz, bandwidth 200Hz
b.Chiratidzo kuwana: 80dB
c.Kuwana kururama: 0.1m
2.Power Supply
a.Yakavakwa-muLi-bhatiri, nominal voltage 7.4V, inokwana 3000mAH.
b.Simba rekushandisa: 300mA, inoenderera yekushanda nguva 9hours.
c.Chaja: kuisa AC220V±10%, 50Hz.Nominal kubuda 8.4V, DC 1A
d.Kuchaja nguva: 4hours
3. Dimension: 270mm * 150mm * 210mm
4. Kurema: 1.5kg.
5. Shandisa mamiriro
Tembiricha -10 ℃--40 ℃, humidity 5-90% RH, urefu <4500m
GD-4133 Cable Fault Detector inoshandiswa kuyera
kureba pakati pezvikanganiso zvetambo.Zviri nyore
inoshanda uye ine hushamwari interface.
Inogona kushandiswa yega pasi peyakaderera voltage pulse mode.U
pasi pemaitiro ekupuruzira ikozvino, inoda kushanda neGD-2131
high voltage jenareta.Pasi peyakawanda pulse mode, GD-4133S
coupler inofanira kushanda pamwe chete.Mushure mekutsvaga chinhambwe, GD-4132 fault locator inofanirwa kushandiswa kuratidza kukanganisa.Zvigadzirwa izvi zvinogona kusanganiswa kuita
seti yekushanda kwepamusoro uye inovandudza tambo yekutadza yekuongorora system.
●7inch LCD skrini, inoshamwaridzana interface.
●Multiple distance yekutsvaga nzira:
Yakaderera voltage pulse nzira: inokodzera kuwanikwa kweiyo yakaderera kuramba kukanganisa, kupfupi dunhu kukanganisa, kuvhurika redunhu kukanganisa.Iyo zvakare inogona kushandiswa mukuyera kwehurefu hwetambo, majoini epakati, T majoini, uye tambo yekumisa kubatana.Iyi nzira zvakare inogona kushandiswa kugadzirisa wave velocity.
Pulse yazvino nzira: Inokodzera kuyera kureba kweiyo yakakwira kuramba kukanganisa, kukanganisa kukanganisa.Uchishandisa yazvino coupler kuunganidza zvikwangwani kubva pasi waya, zvinoita kuti mushandisi kure kure nepamusoro voltage.Iyi nzira yakachengeteka uye yakavimbika.
Multiple pulse: nzira yepamberi yekuyera chinhambwe.Iyo waveform iri nyore kuona uye iko kurongeka kwakakwira.
●200MHz chaiyo-nguva sampling.Max.0.4m kuyerwa kugadziriswa.Iyo ine diki yakafa zone uye yakakosha kune ipfupi tambo uye padyo nemhosva tambo.
●Bata skrini uye wodzvanya kiyi oparesheni
●PIP kopi (pic.kuchengetedza kwenguva pfupi)
Pachave nehwindo guru uye matatu ekuchengetedza kwenguva pfupi windows anogona kutarisa matatu waveforms pamwechete.
●Yakavakwa-mukati yekushandisa system
Yakakosha software manejimendi yekusimudzira software, backup uye kudzoreredza.
●Scale basa
Nzvimbo yekutanga, 10 vanobatika, imwe tambo kukanganisa uye imwe yakazara hurefu inogona kuseta.
Ratidza chiyero uye yekuyedza waveform pamwe chete
●Waveform kuchengetedza uye kutaurirana nekombuta.
Kuchengetwa kwemukati kwemasaveforms.
Ne USB, kurodha kana kurodha data
Kukurukurirana nekombuta
●Kutarisira simba
Backlight inopera simba kana pasina kushanda mu2mins uye simba rinodzima mu10mins kana pasina kushanda.
Yakavakwa-muPolymer Lithium-ion bhatiri.
Nguva yekushanda inosvika maawa mashanu pakushandisa kwega kwega.
Mhosva yakasimba, iri nyore kutakura.
Nzira dzekuwana | Low voltage impulse nzira Impulse ikozvino nzira Multiple impulse method kana inoenderana neGD-4133S |
Max.Sampling frequency | 200MHz |
Gain range | 0-70dB |
Low voltage impulse voltage | 30V |
Max.resolution | 0.4m |
Max.Kutsvaga nzvimbo | 100km |
Dead zone | 2m |
Bhatiri | Nickel-metal hydride rechargeable mabhatiri, kutsungirira nguva kwemaawa mashanu |
Kukurukurirana interface | USB |
Magetsi | Input AC220V,50Hz,yazvino 2A,chaja kwemaawa masere |
Dim. | 274×218×81mm |
Kurema | 3.5kgs |
Operating Temperature | -10 ℃-40 ℃ |
Humidity | 5-90%RH |
Elevation | <4500m |
Iri kushanda pamwe chete neGD-4133 Cable Fault Detector,inoshandiswa kuona yakakwira impedance leak kukanganisa, flashover kukanganisa,yakaderera impedance pasi uye yakavhurika yedunhu kukanganisa kwetambo dzemagetsi.
GD-4133S yakapa pulse coupling chiratidzo cheGD-4133 uyeItsaure kubva kune yakakwira voltage michina.
●Kushandisa tekinoroji yepamusoro yemultiple pulse uye pulse balance.Iyo inoratidzwa waveform iri nyore kuziva.
●Nekuchengetedzwa kweHV, dunhu rekuyeresa uye yakakwira voltage impulse simba inoparadzaniswa nemagetsi.
●Easy wiring, yakachengeteka uye yakavimbika.
●Pulse voltage: 300V (PP)
●Inobvumirwa kuisa impulse voltage: <35kV
●Inobvumirwa kupinza simba rekusimudzira: <2000J
●Simba rekuisa: 220V AC, 50Hz
●Dimension: 560 * 230 * 220mm
●Kurema: 7kg.