Chengetedzo yeOiri Chromatography Analyzer

Chengetedzo yeOiri Chromatography Analyzer

                                                            电力系统专用油色谱分析仪

                                                       HV HIPOT GDC-9560B Simba system Insulation Oiri Gasi Chromatography Analyzer

Kuiswa uye kubvisa chromatographic column:

1. Kuiswa uye kubviswa kwekromatographic column kunofanira kuitwa pane tembiricha yekamuri.

2. Shongwe dzakarongedzwa dzine ferrule seals uye gasket seals.Kune marudzi matatu emaferrules: masimbi esimbi, epurasitiki ferrules uye graphite ferrules, izvo zvisiri nyore kuomeswa zvakanyanya paunenge uchiisa.Gasket-mhando zvisimbiso zvinoda magaskets matsva pese painoiswa mbiru.

3. Kana iyo migumo miviri yekromatographic column yakavharwa negirazi wool.Dzivirira girazi makushe uye kurongedza kubva pakufuridzirwa mumhepo detector neanotakura gasi.

4. Kureba kwekuiswa kwekoramu yecapillary uye kuiswa kunoenderana nebhuku rekuraira rechiridzwa.Chimiro chemakamuri akasiyana echromatographic evaporation akasiyana, uye kureba kwekupinza kwakasiyanawo.Izvo zvinofanirwa kucherechedzwa kuti kana iyo capillary column ikashandiswa nekupatsanurwa kuyerera, iyo interface pakati peiyo vaporization chamber uye packed column haifanire kunge iine maprobes akawandisa akabatana nekamuri inoputika, uye iyo capillary column inofanira kunge iri kunze kwekavha.

 

Kupesvedzera kwechiyero chehydrogen kumhepo pane FID detector:

Mune chromatograph yegasi, reshiyo yehydrogen kumhepo inofanira kuva 1:10.Kana chiyero chakanyanya kukwirira, kunzwa kwehydrogen flame detector kunodonha zvakanyanya.Tarisa hydrogen uye mhepo inoyerera.Kana gasi riri muhydrogen nemhepo risina kukwana, rinoita "bang" kuti ritungidze, uye rinodzima moto, kazhinji paunobatidza chitofu chemagetsi, chinodzimwa, uye chinovhenekera zvakare, uye ipapo hydrogen haina kukwana.

 

Maitiro ekudzivirira jekiseni tsono kubva pakukotama:

Vazhinji vanotanga muchromatography vanowanzo kotamisa tsono uye tsinde nekuti:

1. Chiteshi chejekiseni che chromatograph chegasi chakakoshwa zvakanyanya, uye chakakoshwa zvakanyanya patembiricha yekamuri.Kana tembiricha yekamuri ye vaporization ichiramba ichikwira, iyo silicone gasket ichawedzera uye kuomesa.Panguva ino, zvakaoma kupinda kuburikidza nesirinji.

2. Iyo tsono yakanamirwa muchikamu chesimbi chejekiseni port kana nzvimbo yacho isiri nyore kuwana.

3. Sirinji tsvimbo yakabhenda nekuti simba rakanyanyisa pakubaya sampuli.Kune sampler rack ye chromatographic import.Hazvibviri kupeta simbi yechinyakare sirinji paunenge uchishandisa sampler rack kubaya sampuli.

4. Sezvo rusvingo rwemukati rwesirinji rwakasvibiswa, sundira shaft yetsono kuti ukotame panguva yejekiseni.

5. Iyo gasi chromatograph inofanira kunge yakagadzikana panguva yejekiseni.Kana iwe ukakasira, unokotamisa sirinji.Kana iwe wakajaira kuvhiya uku, kunopera nekukurumidza.


Nguva yekutumira: Jun-07-2022