GDC-9560B Power System Insulation Oil Gasi Chromatograph Analyzer
GDC-9560B Gasi Chromatograph Analyzer ndeyekuongorora iyo gasi yemukati yemafuta ekudzivirira negasi chromatographic nzira.Izvo zvinoshanda kutonga kana iyo yekumhanya ine chikanganiso chingangoita senge-kupisa-kupisa, kuburitsa kana kwete, kuve nechokwadi chekuchengetedzwa kwegidhi remagetsi.Izvo zvinodiwa zvakare kushandiswa kugadzira gasi / mafuta michina yekuongorora michina yavo vasati vabva kufekitori.
Gasi chromatography yekuongorora tekinoroji inzira yekuparadzanisa uye kuongororwa kweakawanda-chikamu musanganiswa.Inonyanya kushandisa mutsauko wekubikira poindi, polarity uye adsorption coefficient yechikamu chega chega mumuenzaniso mukoramu, kuitira kuti zvikamu zvakapatsanurwa mukoromo, uye zvikamu zvakapatsanurwa zviongororwe nemhando uye uwandu.
Iyo gasi chromatograph inoshandisa gasi sechikamu chekufambisa (mutakuri gasi).Kana sampuro yatumirwa kune jekiseni uye vaporized, inotakurwa neanotakura gasi kupinda mukoramu yakarongedzwa kana capillary column nekuda kwekubikira poindi, polarity uye adsorption coefficient yechimwe nechimwe chikamu mumuenzaniso.Musiyano ndewekuti zvikamu zvakapatsanurwa mukoramu, uye ipapo ma detectors akabatana nekoramu anoonekwa sequentially zvichienderana neiyo physicochemical maitiro ezvikamu, uye pakupedzisira masaini akashandurwa emagetsi anotumirwa kune chromatographic workstation.Iyo gasi chromatogram yechikamu chimwe nechimwe inorekodhwa uye kuongororwa nechromatographic workstation kuti iwane kuongororwa mhedzisiro yechikamu chimwe nechimwe.
●Iyo inotora iyo yepamusoro 10/100M inogadzirisa Ethernet yekutaurirana interface uye yakavakirwa-mukati IP protocol stack, iyo inogonesa chiridzwa kuona zviri nyore kuendesa data kureba kuburikidza neLAN yemukati neInternet.Inofambisa kugadzwa kwerabhoritari uye inorerutsa marabhoritari.Iyo gadziriso inofambisa manejimendi ekuongorora data.
●Dhizaini ye3 yakazvimirira yekubatanidza maitiro.Inogona kubatanidzwa nekugadziriswa kwenzvimbo (rabhoritari), zviri nyore kune vatariri kuti vatarise mamiriro ekushanda uye kuongorora mhedzisiro.
●Iyo inosarudzika yeNetChromTM workstation inogona panguva imwe chete kutsigira akawanda machromatographs ekugadzirisa data uye kutonga, kurerutsa dhizaini manejimendi uye kuderedza mushandisi lab investment uye mari yekushandisa.
●Sisitimu muChirungu neChinese, inogona kuchinjika zvakasununguka.
●Nzvimbo yekudzora tembiricha inogona kupihwa zita rakasununguka nemushandisi, izvo zviri nyore kune vashandisi.
●Uchishandisa multiprocessor parallel kushanda modhi, yakagadzikana uye yakavimbika.Inosangana nekuongorora kwakaoma kwemuenzaniso.Yakashongedzerwa neakasiyana-siyana epamusoro-kuita madhijitari akadai seFID, TCD, ECD, uye FPD.Kusvikira ku ina miedzo inogona kuiswa panguva imwe chete.Izvo zvakare zvinogoneka kushandisa iyo detector yekuwedzera nzira, iyo iri nyore kutenga nekuisa mamwe ma detectors mushure mekunge chiridzwa chatengwa.
●Chiridzwa chinotora modular chimiro, chakagadzirwa uye chakatsiviwa, chiri nyore kusimudzira uye kuchengetedza kushanda kwekudyara.
●Iyo itsva microcomputer tembiricha yekudzora tembiricha ine yakanyanya tembiricha yekudzora kurongeka uye kuvimbika kwepamusoro uye anti-kukanganisa kuita.Iyo ine matanhatu akazvimirira akazvimirira ega ekudzora tembiricha masisitimu, ayo anogona kuona 16-nhanho tembiricha hurongwa, izvo zvinoita kuti michina iwedzere kukwanisa kuongorora sampuli.Iyo ine otomatiki yekumashure yekuvhura gonhi system yehovhoni, iyo inovandudza iko kudzika kwetembiricha yekudzora uye inowedzera kumhanya kwekukwira / kudzika.
●Chiridzwa ichi chinogona kuve nechemberi yemagetsi kuyerera controller (EFC) uye yemagetsi pressure controller (EPC) kuona dhijitari, iyo inogona kuvandudza zvakanyanya kuberekana kwehunhu uye huwandu hwemhedzisiro.
●Iyo chiridzwa dhizaini yekumisikidza-yekutanga chirongwa inogona nyore kupedzisa online kuongororwa kwegasi samples (inoda online otomatiki jekiseni zvikamu).
●Iyo inoshanda sisitimu yeiyo yose microcomputer control keyboard iri nyore uye iri nyore kushanda;uye iyo otomatiki yekuzivikanwa tekinoroji ye detector yakagadzirwa.Nekukanganisa kuongororwa uye simba-kudzima data kuchengetedzwa, iwo ma paramita anogona kudzokororwa nemusoro.
●Chiridzwa chine yakavakirwa-mukati ruzha ruzha, yakakwirira resolution 24-bit AD dunhu rine yekutanga kuchengetedza uye yekutanga kubvisa.
●Unganidza masaini echromatographic uye kugadzirisa data, akakodzera WinXP, Win2000, Windows7 uye mamwe masisitimu anoshanda.Sample data inoverengwa kubva kuCDF mafaera anosangana neA/A (American Analytical Society) zviyero, saka inogona kushandiswa neAgilent, Mvura uye mamwe chromatography workstations.
●Chromatographic system ine kodzero dzakazvimiririra yehungwaru, ine yakajairwa interface yeMODBUS/TCP, inogona kuiswa nyore neDCS.
●Icho chiridzwa chinogona kubatanidzwa neauto sampler inogadzirwa nevazhinji vagadziri vepamba uye vekunze;senge Shimadzu AOC-20i, HTA kambani yeHT yakatevedzana yakakwirira-inoshanda mvura, gasi auto sampler.
Kuona magasi | H2, CO, CO2, CH4, C2H4, C2H6, C2H2.(7 magasi),O2(sarudzo), N2 (isarudzo) |
Display | 192*64 dot matrix LCD |
Temperature control area | 6 nzira |
Temperature control range | tembiricha yekamuri +5℃~400℃, kuwedzera 1℃, chokwadi:±0.1℃ |
Programming order | 16 nhanho |
Kukwira kwepurogiramu | 0.1~40℃/min |
Kudzora gasi | mechanical valve control mode, electronic pressure flow control mode optional |
Zviitiko zvekunze | 4 channels |
Injector type | packed column, capillary, matanhatu-nzira vharafu gasi jekiseni, otomatiki headspace jekiseni, etc. |
Nhamba yemadetectors | 4pcs;FID, TCD, ECD, FPD (kusarudza) |
Tanga jekiseni | bhuku, otomatiki sarudzo |
Kukurukurirana interface | Ethernet : IEEE802.3 |
Detector Specifications | |
Hydrogen flame ionization detector (FID) | |
Detection limit | ≤ 2 × 10-11g / s (n-hexadecane / isooctane); |
Baseline ruzha | ≤ 5 × 10-14A |
Baseline drift | ≤ 1 × 10-13A / 30min |
Linear range | ≥106 |
Thermal Conductivity Detector (TCD) | |
Sensitivity | S≥2500mV•ml/mg (benzene/toluene) (yakakurisa 1, 2, 4, 8 nguva zvingasarudzwa) |
Baseline ruzha | ≤20μV |
Baseline drift | ≤30μV/30min |
Linear range | ≥104 |
Electronic Capture Detector (ECD) optional | |
Detection limit | ≤ 1 × 10-13g / ml (propylene hexa-6 / isooctane) |
Baseline ruzha | ≤0.03mV |
Baseline drift | ≤0.2mV/30min |
Linear range | 103 |
Radioactive source | 63Ni |
Flame Photometric Detector (FPD) optional | |
Detection limit | (S) ≤ 5×10-11g/s, (P) ≤ 1×10-12g/s;methyl parathion/ absolute ethanol) |
Baseline ruzha | ≤ 3 × 10-13A |
Baseline drift | ≤ 2 × 10-12A / 30min |
Linear range | Fkana sarufa ≥ 102, yephosphorus ≥ 103 |
Gasi Chromatograph Main Unit | 1 set |
Hydrogen jenareta | 1 set |
Air jenareta | 1 set |
Multi-function Shaker | 1 set |
Standard Pressure Reducing Valve | 1 set |
Nitrogen Pressure Reducing Valve | 1 set |
Nitrogen Cylinder | 1 bhodhoro |
Standard gasi | 1 bhodhoro |
Gasi nzira nzungu M8X1Φ3.2 | 10 pcs |
Majoini ekuderedza vharafu | 5 pcs |
Capillary column nati Φ0.8 | 4 pcs |
Koramu nzungu Φ4.2 uye Φ3.2 | Imwe neimwe 5 pcs |
Simbi yesimbi isina gasi pombi yemukati Φ2 | 10 pcs |
Gasi nzira yekuisa chisimbiso padhi | 50 pcs |
Capillary sampler evaporative pad | 50 pcs |
Capillary graphite pad Φ0.8 | 20 pcs |
Girafu pedhi Φ4.2 uye Φ3.2 | Imwe neimwe 10 pcs |
Fuse | 4 pcs |
Kurisa M3X5 | 6 pcs |
PE gasi pombi Φ3 | 20m |
1 ml yepurasitiki jekiseni | 5 pcs |
100ml jekiseni | 5 pcs |
Tsono | 10 pcs |
20ml girazi jekiseni | 5 pcs |
5ml girazi jekiseni | 5 pcs |
1ml girazi jekiseni | 5 pcs |
Quantitative clip | 2 pcs |
Vaseline 30g | 2 pcs |
Slotted screwdriver 50mm 70mm | Imwe neimwe 1 pc |
Crosshead screwdriver 50mm 70mm | Imwe neimwe 1 pc |
Wrench 8-10 | 1 pc |
Wrench 12-14 | 2 pc |
Mapiritsi emhuno akapinza | 1 pc |
Ground cable | 1 pc |
Chiratidzo tambo | 1 pc |
Tambo yemagetsi | 1 pc |
Rubber cap | 20 pc |
Aluminium foil bag | 2 pcs |
Tsono mbiri | 25 pcs |
Disk | 1 pc |
Kukurukurirana tambo | 1 pc |
Gasi block | 1 pc |