GLF-314 SF6 Gasi Infrared Imaging Leak Detector
● Intuitive kuratidzwa kwegasi leak status munguva chaiyo.
● Gasi-enhanced infrared mode kuti ione kubuda kwegasi kuduku.
● Embedded operating system, UI design yakafanana nefoni uye tablet inoita kuti zvive nyore kuti vashandisi vatange.
● USB, WiFi, HDMI nzira dzakawanda dzekutumira data.
● High-resolution rotatable LCD kuratidza.
● High-resolution viewfinder ine inogadziriswa kona yechiedza chakajeka.
● Chigadzirwa chisingaremi, chakasimba.
● Anti-kuneta ergonomic design.
● Thermal imager host
● Adapta yemagetsi
● Lithium-Ion rechargeable mabhatiri uye majaja
● USB tambo
● HDMI vhidhiyo cable
●32G TF memori kadhi uye kadhi kuverenga
● Bhuku rekushandisa
● Bhokisi rokurongedzera
N0. | Items | Zvinotsanangurwa | |
1 | Detector uye optical parameters | Detector type | Isina kutonhorerainfrareddetectors |
2 | Infrared resolution | 384×288 | |
3 | Pixel spacing | 25μm | |
4 | Sefa bhendi remhinduro yewavelength | 7μm–8.5μm,9.5μm -12μm | |
5 | Thermal senitivity (NETD) | <0.1℃@30℃ | |
6 | Detectable gasi | 7μm–8.5μm:CH4 9.5μm -12μm: SF6 | |
7 | Infrared lens | Standard lens(21.7°±2°)× (16.4°±2°) | |
8 | Infrared focus | Manual & auto | |
9 | Mufananidzo kuratidza | Digital zoom | 1 kusvika 10 nguva inoenderera yedhijitari zoom |
10 | Chimiro chemufananidzo | 50Hz±1Hz | |
11 | Ratidza resolution | 1024×600 | |
12 | Ratidza skrini | 5-inch touch screen, resolution 1024×600 | |
13 | Viewfinder | OLED yakakwirira-resolution kuratidza, 1024 x 600 pixels | |
14 | Display mode | Infrared mode. Gasi boost mode. Infrared tembiricha kuyerwa mode. Visible light mode. Mufananidzo-mu-pikicha mode. Fusion mode; | |
15 | Kugadzirisa mufananidzo | Otomatiki uye bhuku kupenya uye musiyano kugadzirisa | |
16 | Palette | 10 mhando + 1 mushandisi-yakatsanangurwa | |
17 | Digital kamera | Munda wekuona unopindirana neiyo infrared lens | |
18 | Mwenje dze LED | Ehe | |
19 | Kuyera kuyera uye kuongorora | Kuyera kuyerwa kwemhando | 1 giya:-20 - 150°C 2 giya:100 — 650°C |
20 | Kururama | ±3℃or ±3%(Tora kukosha kukuru, tembiricha yepakati i15°C kusvika 35°C) | |
21 | Center point tembiricha kuyerwa | Ehe | |
22 | Movable point tembiricha kuyerwa | Inotsigira gumi mapoinzi | |
23 | Movable area tembiricha kuyerwa | Inotsigira gumi madenderedzwa uye gumi rectangles | |
24 | Movable line tembiricha kuyerwa | Inotsigira mitsara gumi | |
25 | Yakakwirira uye yakaderera tembiricha pointing | Tsigira yakazara-screen yakakwirira uye yakaderera tembiricha poindi yekumisikidza uye yakakwirira uye yakaderera tembiricha poindi yekumisikidza munzvimbo | |
26 | Measurement presets | Hapana kuyerwa, nzvimbo yepakati, yakanyanya tembiricha poindi, shoma tembiricha poindi, avhareji tembiricha | |
27 | Tembiricha alarm | Ruvara maaramu (isothermal mitsetse): pamusoro/pazasi akatarwa tembiricha mazinga, pakati petembiricha yakatarwa. Measurement function alarms: Zvinonzwika maaramu (pamusoro/pazasi/pakati petembiricha yakatarwa). | |
28 | Kururamisa kukosha kwakayerwa | Emissivity (0.01 kusvika 1.0 inosarudzwa), inoratidzwa tembiricha, hunyoro hunoenderana, tembiricha yemuchadenga, chinhambwe chechinangwa, muripo wekunze wehwindo | |
29 | Date kuchengetedza | Storage medium | Inobviswa TF memori kadhi |
30 | Tora mifananidzo nguva dzose | 3 masekonzi kusvika maawa makumi maviri nemana | |
31 | Native full radiometric image analysis | Yakachengetedzwa radiometric inopisa mifananidzo inogona kugadziridzwa uye kuongororwa pakhamera | |
32 | Image file format | Yakajairika JPEG mifananidzo, inosanganisira mapikicha edhijitari uye yakazara radiometric data | |
33 | Radiometric infrared vhidhiyo kurekodha | Real-time radiation vhidhiyo kurekodha, * .raw faira inochengetwa muTF kadhi | |
34 | Non-radiative infrared vhidhiyo kurekodha | *.avi vhidhiyo faira, chengetedza kuTF kadhi | |
35 | Chirevo chemufananidzo | Izwi: 60 masekondi, akachengetwa nemufananidzo Chinyorwa: Wedzera tafura, sarudza pakati peakafanotsanangurwa matemplate | |
36 | Remote display view | Wona vhidhiyo inoyerera munguva-chaiyo pamusoro peWi-Fikubatana. Batanidza kuratidza kuburikidza neHDMI yakakwirira-tsanangudzo interface; | |
37 | Remote operation control | Batanidza kune yakatsaurirwa software kutonga kuburikidza neWi-Fi; | |
38 | Kukurukurirana uye peripherals | interface | USB 2.0, Wi-Fi, HDMI |
39 | WIFI | Ehe | |
40 | Vadivelu Comedy Audio | Maikorofoni uye mutauri wemufananidzo izwi chirevo uye kurekodha vhidhiyo | |
41 | laser pointer | Ehe | |
42 | GPS | Tsigira satellite chinzvimbo, ruzivo rwenzvimbo runogona kuchengetwa mumufananidzo | |
43 | Magetsi | Bhatiri mhando | Rechargeable lithium yemagetsi bhatiri |
44 | Battery voltage | 7.4v | |
45 | Kuenderera mberi nguva yekushanda | Kwete asingasviki maawa mana pakamuri tembiricha | |
46 | Kunze simba rekupa | Tsigira kunze dc12v magetsi ekupa | |
47 | Kutarisira simba | Kudzima otomatiki kana otomatiki chidzitiro chakadzimwa, nguva inogona kusarudzwa kubva kusambofa, 5min, 10min, 30min. | |
48 | Kuchinjika kwezvakatipoteredza
| Kushanda tembiricha | -20-+50 ℃ |
49 | Kuchengetedza tembiricha | -40-+70 ℃ | |
55 | Zvinhu zvemuviri | Huremu (pasina bhatiri) | ≤ 1.8 kg |
56 | Dimensions (H*W*L) | ≤185 mm × 148 mm × 155 mm (kusanganisira standard lens) | |
57 | Tripod gomo base | Standard,1/4"-20 |
● Intuitive kuratidzwa kwegasi leak status munguva chaiyo.
● Gasi-enhanced infrared mode kuti ione kubuda kwegasi kuduku.
● Embedded operating system, UI design yakafanana nefoni uye tablet inoita kuti zvive nyore kuti vashandisi vatange.
● USB, WiFi, HDMI nzira dzakawanda dzekutumira data.
● High-resolution rotatable LCD kuratidza.
● High-resolution viewfinder ine inogadziriswa kona yechiedza chakajeka.
● Chigadzirwa chisingaremi, chakasimba.
● Anti-kuneta ergonomic design.
● Thermal imager host
●Mugadziri wemagetsi
●Lithium-Ion mabhatiri uye majaja anogona kuchajwa
● USB tambo
● HDMI vhidhiyo cable
●32G TF memori kadhi uye kadhi kuverenga
● Bhuku rekushandisa
● Bhokisi rekurongedzera
N0. | Items | Zvinotsanangurwa | |
1 | Detector uye optical parameters | Detector type | Isina kutonhorerainfrareddetectors |
2 | Infrared resolution | 384×288 | |
3 | Pixel spacing | 25μm | |
4 | Sefa bhendi remhinduro yewavelength | 7μm–8.5μm,9.5μm -12μm | |
5 | Thermal senitivity (NETD) | <0.1℃@30℃ | |
6 | Detectable gasi | 7μm–8.5μm:CH4 9.5μm -12μm: SF6 | |
7 | Infrared lens | Standard lens(21.7°±2°)× (16.4°±2°) | |
8 | Infrared focus | Manual & auto | |
9 | Mufananidzo kuratidza | Digital zoom | 1 kusvika 10 nguva inoenderera yedhijitari zoom |
10 | Chimiro chemufananidzo | 50Hz±1Hz | |
11 | Ratidza resolution | 1024×600 | |
12 | Ratidza skrini | 5-inch touch screen, resolution 1024×600 | |
13 | Viewfinder | OLED yakakwirira-resolution kuratidza, 1024 x 600 pixels | |
14 | Display mode | Infrared mode. Gasi boost mode. Infrared tembiricha kuyerwa mode. Visible light mode. Mufananidzo-mu-pikicha mode. Fusion mode; | |
15 | Kugadzirisa mufananidzo | Otomatiki uye bhuku kupenya uye musiyano kugadzirisa | |
16 | Palette | 10 mhando + 1 mushandisi-yakatsanangurwa | |
17 | Digital kamera | Munda wekuona unopindirana neiyo infrared lens | |
18 | Mwenje dze LED | Ehe | |
19 | Kuyera kuyera uye kuongorora | Kuyera kuyerwa kwemhando | 1 giya:-20 - 150°C 2 giya:100 — 650°C |
20 | Kururama | ±3℃or ±3%(Tora kukosha kukuru, tembiricha yepakati i15°C kusvika 35°C) | |
21 | Center point tembiricha kuyerwa | Ehe | |
22 | Movable point tembiricha kuyerwa | Inotsigira gumi mapoinzi | |
23 | Movable area tembiricha kuyerwa | Inotsigira gumi madenderedzwa uye gumi rectangles | |
24 | Movable line tembiricha kuyerwa | Inotsigira mitsara gumi | |
25 | Yakakwirira uye yakaderera tembiricha pointing | Tsigira yakazara-screen yakakwirira uye yakaderera tembiricha poindi yekumisikidza uye yakakwirira uye yakaderera tembiricha poindi yekumisikidza munzvimbo | |
26 | Measurement presets | Hapana kuyerwa, nzvimbo yepakati, yakanyanya tembiricha poindi, shoma tembiricha poindi, avhareji tembiricha | |
27 | Tembiricha alarm | Ruvara maaramu (isothermal mitsetse): pamusoro/pazasi akatarwa tembiricha mazinga, pakati petembiricha yakatarwa. Measurement function alarms: Zvinonzwika maaramu (pamusoro/pazasi/pakati petembiricha yakatarwa). | |
28 | Kururamisa kukosha kwakayerwa | Emissivity (0.01 kusvika 1.0 inosarudzwa), inoratidzwa tembiricha, hunyoro hunoenderana, tembiricha yemuchadenga, chinhambwe chechinangwa, muripo wekunze wehwindo | |
29 | Date kuchengetedza | Storage medium | Inobviswa TF memori kadhi |
30 | Tora mifananidzo nguva dzose | 3 masekonzi kusvika maawa makumi maviri nemana | |
31 | Native full radiometric image analysis | Yakachengetedzwa radiometric inopisa mifananidzo inogona kugadziridzwa uye kuongororwa pakhamera | |
32 | Image file format | Yakajairika JPEG mifananidzo, inosanganisira mapikicha edhijitari uye yakazara radiometric data | |
33 | Radiometric infrared vhidhiyo kurekodha | Real-time radiation vhidhiyo kurekodha, * .raw faira inochengetwa muTF kadhi | |
34 | Non-radiative infrared vhidhiyo kurekodha | *.avi vhidhiyo faira, chengetedza kuTF kadhi | |
35 | Chirevo chemufananidzo | Izwi: 60 masekondi, akachengetwa nemufananidzo Chinyorwa: Wedzera tafura, sarudza pakati peakafanotsanangurwa matemplate | |
36 | Remote display view | Wona vhidhiyo inoyerera munguva-chaiyo pamusoro peWi-Fikubatana. Batanidza kuratidza kuburikidza neHDMI yakakwirira-tsanangudzo interface; | |
37 | Remote operation control | Batanidza kune yakatsaurirwa software kutonga kuburikidza neWi-Fi; | |
38 | Kukurukurirana uye peripherals | interface | USB 2.0, Wi-Fi, HDMI |
39 | WIFI | Ehe | |
40 | Vadivelu Comedy Audio | Maikorofoni uye mutauri wemufananidzo izwi chirevo uye kurekodha vhidhiyo | |
41 | laser pointer | Ehe | |
42 | GPS | Tsigira satellite chinzvimbo, ruzivo rwenzvimbo runogona kuchengetwa mumufananidzo | |
43 | Magetsi | Bhatiri mhando | Rechargeable lithium yemagetsi bhatiri |
44 | Battery voltage | 7.4v | |
45 | Kuenderera mberi nguva yekushanda | Kwete asingasviki maawa mana pakamuri tembiricha | |
46 | Kunze simba rekupa | Tsigira kunze dc12v magetsi ekupa | |
47 | Kutarisira simba | Kudzima otomatiki kana otomatiki chidzitiro chakadzimwa, nguva inogona kusarudzwa kubva kusambofa, 5min, 10min, 30min. | |
48 | Kuchinjika kwezvakatipoteredza
| Kushanda tembiricha | -20-+50 ℃ |
49 | Kuchengetedza tembiricha | -40-+70 ℃ | |
55 | Zvinhu zvemuviri | Huremu (pasina bhatiri) | ≤ 1.8 kg |
56 | Dimensions (H*W*L) | ≤185 mm × 148 mm × 155 mm (kusanganisira standard lens) | |
57 | Tripod gomo base | Standard,1/4"-20 |