GDWG-IV SF6 Gasi Leak Detector(IR Series)
GDWG-IV SF6 Gasi Leak Detector is infrared red type leak detector (NDIR tekinoroji).Iri ruvara OLED kuratidza uye chaiyo-nguva inoratidza SF6 kutariswa.Inokurumidza kuona SF6 breaker, GIS leakage point uye gore rega rega rekudonha chiyero chemhando uye nehuwandu.Chishandiso chakanaka chakakodzera dhipatimendi rekupa magetsi, kuisirwa uye overhaul unit, simba rekuyedza Institute.
●High Voltage Switch Equipment
●Rotor vane helikopta
●Gas transmission system
●Kuona chidzimisa moto
●Ventilation kunyatsoita tsvakiridzo yeZvivakwa
●Kuona njodzi
●Hapana mwaranzi.
●Hapana chikonzero chekutsiva yakakwira yakakwira yakachena argon gasi nguva dzose.
●Hapana chikonzero chekuswedera kune high pressure gasi.
●Hapana chikonzero chekutsiva masensa nguva dzose, inodhura-inoshanda.
●Kuita kwakadzikama, mutengo wakaderera wekugadzirisa.Hapana chikonzero chekugadzira mutsara calibration gore rega rega.
●Hapana kukanganisa nehunyoro uye kusvibiswa kwezvakatipoteredza.
●Kunzwa kwakanyanya, kusvika ku0.01ppmv.
●Kana yakakomba kuvuza kana iyo SF6 gasi yekumisikidza yasvika zana muzana, haizosvibiswa kana kukuvara.
●OLED kuratidza.
●Yakavakwa-mukati Lithium bhatiri.
●Mushandisi-inotsanangurwa alarm ine ruzha uye chiedza.
●Kunzwa kwakanyanya uye kugadzikana kwakanaka.
●Yekukurumidza kuyerwa kumhanya, nguva inosvika kuma3s.
●Tembiricha uye pressure muripo.
●Mhinduro chete yeSF6 gasi, kwete yeimwe gasi.
●Saizi diki, iri nyore kutakura, yakakodzera kune-saiti kushanda.
●Negasbag isina-slip tambo, yakasununguka kutakura.
●Kuchengetedza data kusvika ku8000groups.
●Super-light aluminium ine yakazara shielding shell.
●Pasuru yekunze inoshandisa purasitiki yeinjiniya, ine-uchapupu hwemvura, guruva-uchapupu.
●Nheyo yekuyeresa: Isiri-inoparadzira infrared sensor (NDIR)
●Kuyera huwandu: 0-5000ppm SF6
●Kururama: ±2%FS(0-1000ppm)
●Kudzokorora kukanganisa: ≤±1%
●Sensitivity: 0.01ppmv
●Nguva yekupindura: ≤3s
●Nguva yekudzorera: ≤5s
●Kugadzikana: ≤± 20ppm, anopfuura 1000hours
●Zero shift: ≤±1% (FS/gore)
●Linear kukanganisa: ≤±1%
●Kuchengetedza tembiricha: -20°+60℃
●Kushanda tembiricha: -20°+50℃
●Sampling mode: Yakavakwa-mu electromagnetic diaphragm pombi, otomatiki slot-mumhando, inoyerera inosvika 1L/min.
●Kushanda magetsi: 220VAC±10%,50Hz Kana Yakavakwa-muLi-bhatiri.
●Dimension: 140×235×83mm
●Kurema: anenge 1.5kg
CT/PT Tester | 1chidimbu |
Test Lead | 1set |
Earth cable | 1chidimbu |
Tambo yemagetsi | 1chidimbu |
2A fuse | 2pcs |
Gwaro remushandisi | 1kopi |
Factory test report | 1kopi |