GDCR-3200C Double Clamp Multifunctional Earth Resistance Tester
GDCR3200C Kaviri Clamp Multifunctional Earth Resistance Tester yakanyatsogadzirwa uye inogadzirwa kune-saiti kuyerwa kwepasi kuramba, registivity yevhu, grounding voltage, grounding line leakage current, AC current uye DC kuramba.Chiridzwa chinotora tekinoroji yedhijitari yekugadzirisa tekinoroji, ine 2-waya nzira, 3-waya nzira, 4-waya nzira, nzira yekusarudza, kaviri clamp nzira uye dzimwe nzira dzekuyera;Kupinza FFT (Fast Fourier Transform) tekinoroji, AFC (Automatic Frequency Control) tekinoroji, ine yakasarudzika anti-kupindira kugona uye kuchinjika kwezvakatipoteredza, yakakwirira inodzokororwa bvunzo kuenderana, kuve nechokwadi chepamusoro, kugadzikana kwepamusoro uye kuvimbika kwepamusoro pakuyera kwenguva refu.Chiridzwa chakashandiswa chakashandiswa. hombe caliber yazvino clamp dhizaini, inogona kubata nemhando dzese dzebvunzo zvinodiwa, inogona kuyera kudzika kwekupokana kwehukuru hukuru pasi pasi mutobvu, inochinjika kuyera kukosha kwekupokana kweiyo imwe poindi uye gidhi yepasi uye ese marudzi ese akaomarara ekugadzirisa mamiriro, hapana chikonzero chekubvisa chero parallel yekubatanidza pasi danda paunenge uchiyera parallel grounding system, inovandudza zvakanyanya kurongeka kweyero, nekuti bvunzo yekuisa pasi inopa mhinduro yakakwana.
GDCR3200C Double Clamp Multifunctional Earth Resistance Tester inoumbwa nemuchina wekugamuchira, chibatiso chazvino (double clamp), waya dzekuyedza, simbi yepasi, software yedata uye waya dzekutaura zvichingodaro.Iyo hombe yeLCD kuratidzwa kwemuchina wekugamuchira ane chena backlight uye bar graph chiratidzo chinogona kuoneka zvakajeka.Iyo tester ine basa rekuchengetedza, basa rewachi, uye inongochengeta 2000 mapoka ebvunzo mhinduro ine zuva nenguva.Muongorori ane Bluetooth yekutaurirana basa rinotsigira Android system.Mushure mekuisirwa APP, inogona kuyedza kana kuverenga marekodhi ebvunzo munharembozha, ichiunza chiitiko chitsva.Iyo tester inoshongedza USB interface, uye iyo yakachengetwa data inogona kuiswa kuPC kuburikidza ne USB interface.Iyo yekutaurirana software inogona kuona mabasa ekuverenga, kubvunza, kuchengetedza, kushuma uye kudhinda yenhoroondo rekodhi data.Inoshandiswa zvakanyanya musimba, kufonera, meteorology, minda yemafuta, kuvaka, kudzivirira mheni uye zvigadzirwa zvemagetsi zvemaindasitiri.
●Yakasarudzika dhizaini yeiyo jack chiratidzo mwenje, chaiyo chiratidzo cheiyo jack chinzvimbo, dzivisa kushanda kukanganisa.
●Magiya basa rekusarudza knob, nzira dzakasiyana dzekuedza dzinoratidzwa, zvichiita kuti kushanda kuve nyore uye nekukurumidza.
●Iyo tester ine Bluetooth yekutaurirana basa uye inotsigira Android system.Vashandisi vanogona kushandisa nharembozha kuyedza kushanda kana kuverenga mhinduro dzine zuva uye nguva zviri nyore.
●Icho chiridzwa chinotora bhokisi rekudzivirira mvura, iro rakasimba, rakachengeteka uye rinogara kwenguva refu yekudzivirira-kurovera, kusadonha uye kusapinda mvura (yekudzivirira giredhi IP65), kunyanya yakakodzera kushandiswa munzvimbo dzekunze dzekuvaka.
●Iyo mita inoshongedzerwa nehukuru hukuru rechargeable lithium bhatiri pack.Uye ne USB interface yekurodha data basa.
Basic mamiriro & Basa mamiriro
Kupesvedzera Quantity | Base Condition | Mamiriro Ekushanda | Remark |
Ambient Temp | 23℃±1℃ | -10 ℃-40 ℃ | ---- |
Ambient Humidity | 40% -60% | <80% | ---- |
Kushanda Voltage | 7.8V±0.1V | DC 7.8V±0.6V | ---- |
Webetsero Earth Resistance | <100Ω | <5kΩ | |
Kupindira Voltage | Unofanira kudzivisa | <20V | |
Kupindira Current | Unofanira kudzivisa | <2A | |
Electrode Distance pakuyera R | a>5d | a>5d | |
Electrode Distance pakuyera ρ | a>20h | a>20h |
General specification
Function | Kuyera kupikisa kwepasi, kusagadzikana kwevhu;DC kuramba, pasi voltage, alternating current, leakage current | |
Magetsi | DC 7.4V 2600mAh rechargeable lithium bhatiri, rizere ne8.4V | |
Backlight | Controllable screen backlight, inokodzera nzvimbo dzakadzima | |
Kuyera Nzira | DC kuramba | DC kuramba 2-waya nzira |
DC kuramba 4-waya nzira | ||
Kuramba kwepasi | Earth resistance 2-waya nzira | |
Earth resistance 3-waya nzira | ||
Earth resistance 4-waya nzira | ||
Earth kuramba single clamp 3-waya nzira (sarudzo nzira) | ||
Earth kuramba single clamp 4-waya nzira (sarudzo nzira) | ||
Earth resistance double clamp nzira | ||
Soil resistivity (Wenner nzira) | ||
Earth current | Ikozvino clamp kuyerwa | |
Earth voltage | Avhareji yekugadzirisa | |
Test Voltage Wave | Sine wave | |
Test Frequency | 128Hz/111Hz/105Hz/94Hz(AFC) | |
Short-circuit Test Current | AC 250mA max | |
Open-circuit Test Current | AC 40V huru | |
Electrode Distance Range | 1m-100m | |
Display Mode | 4-digital hombe LCD kuratidza, ine chidzitiro backlight | |
Measuring Indicator | Munguva yekuyera, LED flash chiratidzo, LCD kuverenga pasi kuratidza | |
LCD Frame Dimension | 128mm × 75mm | |
LCD nzvimbo yekuratidzira | 124mm × 67mm | |
Instrument Dimension | 280mm(L) X 260mm(W) X 160mm(H) | |
CT Saizi | 223mm X 120mm X 39mm | |
Test Wire | 4 waya: imwe neimwe ndeye tsvuku 20m, nhema 20m, yero 10m, uye yegirini 10m | |
Simple Test Wire | 2 waya: imwe neimwe yetsvuku 1.6m uye dema 1.6m | |
Webetsero Grounding Rod | 4PCS: Φ10mm X150mm | |
Current Clamp | 2PCS :1 yeblue-black plug uye 1 red-black plug | |
Clamp Caliber | Φ70mm | |
Clamp Lead Wire | 2m | |
Kuyera Chiyero | AC ikozvino: inenge 2 nguva / sekondi | |
Earth Voltage: inenge 2 nguva / sekondi | ||
Kuramba kwepasi: anenge 7 masekondi / nguva | ||
Kuyera Nguva | Kupfuura 5000 nguva (Ipfupi-yedunhu bvunzo, nguva yekupindirana inofanira kunge inosvika makumi matatu masekonzi) | |
Line Voltage | Kuyera pazasi AC 600V | |
Communication Interface | Bluetooth module, USB interface, data rekuchengetedza rinogona kurodha pakombuta, kuchengetwa kana kudhindwa. | |
Kukurukurirana Waya | USB kutaurirana waya x1pcs, nehurefu 1.5m | |
Data Hold | Data kubata basa: "BATA" chiratidzo kuratidza | |
Data Storage | 2000 mapoka, "MEM" chiratidziro chekuchengetedza, "FULL" chiratidzo cheflash kuratidza chengetedzo yakazara | |
Data Access | Data kuverenga basa: VERENGA" chiratidzo kuratidza | |
Kufashukira Kuratidzwa | Kupfuura kuyera huwandu hwekufashukira basa: "OL"chiratidzo chekuratidzira | |
Yakaderera Yazvino Chiratidzo cheChibatiso Chazvino | Chiyero nenzira yekusarudza kana mbambo yakapetwa kaviri, chiratidzo chazvino chinogamuchirwa neCT2 chakaderera pane 0.5mA, chicharatidza "", uye chinofanira kutarisa kurovera kweiyo CT2 ikozvino clamp. | |
Kupindira Muedzo | Kuzvizivisa otomatiki kwemasaini ekukanganisa, "NOISE" chiratidzo chechiratidzo kana magetsi ekupindira akakwira kupfuura 5V. | |
Webetsero Grounding Test | Iine yebetsero ivhu rekudzivirira bvunzo basa, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ) | |
Alarm Basa | Kuyera kukosha kunodarika kukosha kwekuseta, kuchaita kuti "Toot-toot-toot" alarm ruzha. | |
Battery Voltage | Nepo simba rebhatiri richidzika kusvika pa7.2V ± 0.1V, rinoratidza bhatiri voltage yakaderera chiratidzo, uye chiyeuchidzo kutsiva bhatiri. | |
Automatic Shutdown | Zvivhare otomatiki mushure memaminitsi gumi nemashanu ekubatidza magetsi | |
Kushanda Current | Backlight: 25mA Max (chete backlight simba rekushandisa) | |
Standby: 25mA Max (Backlight yadzimwa mushure mekuita simba) | ||
Chiyero: 150mA Max (Backlight yakavharwa) | ||
Kurema | Muedzi: 2290g | |
Ikozvino Clamp: 1100g (2pcs) | ||
Huremu hwese: 6800g (inosanganisira zvese zvekushandisa) | ||
Kushanda Tembiricha & Humidity | -10 ℃-40 ℃, pasi pe80% rh | |
Kuchengetedza tembiricha & humidity | -20 ℃-60 ℃, pazasi 70% rh | |
Dziviriro Level | IP65 (vhara kesi) | |
Overload Protection | Kuyera kuramba kwepasi: pakati peimwe neimwe nzvimbo yeC (H) -E,P(S)-ES, AC 280V/3 masekondi | |
Insulation Resistance | Kupfuura 20MΩ(pakati pedunhu nekunze goko iri 500V) | |
Withstanding Voltage | AC 3700V/rms.(Pakati pedunhu nekunze goko) | |
Electromagnetic Features | IEC61326(EMC) | |
Dziviriro Type | IEC61010-1(CAT Ⅲ 300V,CAT IV 150V,Kusvibiswa 2); IEC61010-031; IEC61557-1 (Pasi kuramba); IEC61557-5 (Ivhu rekudzivirira); JJG 366-2004 (Grounding resistance mita) JJG 1054-2009 (Clamp grounding resistance mita) |