Tsanangudzo yeCapacitance & Tan Delta Tester
capacitance & tan delta tester inzira yakakosha mukuyedza kuyedza, iyo inogona kunyatso tarisa kushata kwehunyoro hwemagetsi emidziyo yemagetsi, pamwe nekukanganisa kwenzvimbo.Yakasiyana frequency otomatiki capacitance & tan delta tester ndeye yakakwirira-chaiyo bvunzo chiridzwa chakazvimiririra chakagadzirwa neHV Hipot.Inonyanya kushandiswa kuyera capacitance & tan delta tangent uye capacitance yemhando dzakasiyana-siyana dzemagetsi emagetsi mumagetsi emagetsi, zviteshi uye mamwe minda kana mumarabhoritari.Yakasiyana frequency otomatiki capacitance & tan delta tester inogona kunyatso kuwana kuderera kwehunyoro hwese uye kukanganisa kwenzvimbo kwemagetsi emidziyo yekuisa.Inoshandiswa zvakanyanya mukuyera & tan delta kuyerwa kwevashanduri, ma transformer, tambo dzemagetsi uye zvimwe zvishandiso muindasitiri yemagetsi.
GD6800 capacitance & tan delta tester
Kushandiswa kwecapacitance & tan delta tester
capacitance & tan delta inoshandiswa zvakanyanya mukugadzira magetsi, kuiswa kwemidziyo yemagetsi, handover uye kudzivirira kuyedzwa.Chiridzwa chacho chakakodzerawo kuyera tgδ uye kukwanisa kwemagetsi emagetsi akakwirira mumashopu, marabhoritari uye zvikamu zvekutsvakurudza kwesayenzi;inogona kushandiswa kuyedza iyo capacitance & tan delta yemafuta ekuvharisa kana akashongedzerwa neinodzivirira mafuta makapu.
Hunhu hwe capacitance & tan delta tester
Icho chiridzwa chimiro chakabatanidzwa chine chakavakirwa-mukati capacitor uye inosimudzira simba rekupa, diki diki, huremu huremu, nyore kutakura, nyore kushanda, otomatiki kuyerwa, intuitive kuverenga, hapana kutendeuka, yakakwira chaiyo, uye yakasimba kupesana-kukanganisa kugona.
Chimiro che capacitance & tan delta tester
Chiridzwa chacho chine high-voltage step-up transformer, uye yakatora matanho ekuchengetedza ekuchengetedza akadai se zero-kuyambuka kuvhara uye kudzivirira mheni.Munguva yekuedzwa, wedzera zvakananga 220V AC magetsi, inogona kubuda 2KV, 5KV, 10KV mazinga akasiyana emagetsi akakwira, kushanda kuri nyore uye kwakachengeteka.
Basa re capacitance & tan delta tester
Ichi chiridzwa chiridzwa chepamusoro-chakanyanya kuyera chiyero che capacitance & tan delta yemhando dzakasiyana-siyana dzemagetsi emagetsi mumagetsi emagetsi, zviteshi uye mamwe minda, uye inogona kuvimbisa kuyerwa kwakaringana pasi pesimba remagetsi kupindira.Chiridzwa chakawedzera Chinese menyu basa, kushanda kuri nyore uye kuri nyore.Kushanda kumwe chete, iyo microcomputer inopedzisa otomatiki maitiro ese ekuyera.Ndiyo yakanaka capacitance & tan delta yekuyera michina.
Kuyera nzira ye capacitance & tan delta tester
Iyo yakakwira-voltage midziyo yemagetsi isina kudzika kana kuti yakananga pasi inogona kuyerwa nemberi uye reverse wiring nzira.
Nguva yekutumira: Mar-16-2022