-
GDRB-B Transformer Frequency Response Analyzer
Power transformer winding deformation tester (frequency response method) is based on the measurement of characteristic parameters of transformer internal windings, adopts the internal fault frequency response analysis (FRA) method, can accurately judge the internal faults of transformers.
-
GDZRS-20B Three Phase DC Winding Resistance Tester
GDZRS-20B Three Phase DC Winding Resistance Tester is a new generation of rapid tester that integrates magnetization method testing, three-phase testing (Yn, Y, △) and degaussing functions. It is an ideal equipment for measuring the DC resistance of large power transformers. The screen adopts a large-screen high-resolution LCD, which is convenient for on-site use. All direct resistance test items can be completed with one connection. The test speed is fast, the accuracy is high, and the measuring range is wide.
-
GDZRC-10H Hand-held Transformer DC Winding Resistance Tester
GDZRC-10H Hand-held Transformer DC Winding Resistance Tester is not only suitable for the measurement of inductive test object such as transformer, CT/PT and reactor, but also for the measurement of resistive test object such as copper bar, wire and switch contact
As a newly-designed product, it has features of small size, fast test speed and high accuracy. -
GDOT-80C Insulation Oil Breakdown Tester 80kV
There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation.
-
GDRB-C Power Transformer Winding Deformation Tester
Power transformer winding deformation tester (frequency response method) is based on the measurement of characteristic parameters of transformer internal windings, adopts the internal fault frequency response analysis (FRA) method, can accurately judge the internal faults of transformers.
-
GDZRC-20A DC Winding Resistance Tester
GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
It has the features of fast measurement, small size and high accuracy of measurement,which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment. -
GDOT-100C Insulation Oil Breakdown Tester 100kV
GDOT-100C Insulation Oil Breakdown Tester is fully digital industrial instrument with microcomputer control. It has the features of high accuracy and strong anti-interference ability.
-
GDRB-F Transformer Winding Deformation Tester (SFRA & Impedance Method)
GDRB-F Transformer winding deformation tester adopts sweep frequency response analysis (SFRA) method and impedance method to detect transformer winding movements and mechanical failures due to mechanical shock, transportation or short circuits, with features of fast test speed, high frequency stability and powerful analysis software.
-
GDZRC-20U Series DC winding resistance tester
GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.
It has the features of fast measurement, small size and high accuracy of measurement, which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment. -
GDOT-100D 100kV Insulation Oil Tester
In power system, railway system and large petrochemical industrial enterprises all have a lot of electrical equipment, its internal insulation is mostly oil-filled insulation type.
-
GDZRC-40A Series DC Winding Resistance Tester
GDZRC series DC winding resistance tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors. It has the features of fast measurement, small size and high accuracy of measurement,which is ideal equipment of measuring transformer winding and DC resistance of big power inductance equipment.
-
GD6100 Insulation Oil Tan Delta Tester (Oil Dissipation Factor Tester)
GD6100 is high-precision instrument for testing dielectric loss angle and volume resistivity of insulating oil or other insulating liquids.