Products

  • GDB-II Transformer Inoshandura Ratio Tester

    GDB-II Transformer Inoshandura Ratio Tester

    Zvinoenderana neIEC uye zvinoenderana nemitemo yenyika, iyo yeshanduro chiyero bvunzo chinhu chinofanira-kuita panguva yekugadzira, mushandisi handover, uye overhaul bvunzo yemagetsi anoshandura.Izvi zvinogona kunyatso tarisa kunaka kwezvigadzirwa zvetransformer panguva yekuendesa uye kushandiswa, uye kudzivirira mapfupi maseketi, akavhurika dunhu, kushamwaridzana kusiri pakati pekushandura kutendeuka, uye kutadza kwemukati kana kutadza kubata kweiyo regulator switch.

    Nechikonzero ichi, iyo reshiyo tester GDB-II yakagadziridzwa uye inogadzirwa nekambani yedu inoita kuti mashandiro acho ave nyore, azere mabasa, akagadzikana uye akavimbika data, uye inovandudza zvakanyanya kumhanya kwekuyedza zvinoenderana nezvinodiwa nemushandisi pa-saiti yekushandisa pane yekutanga hwaro.Iyo inosangana nezvinodiwa zveakasiyana akakura, epakati, uye madiki oiri transformer ratio bvunzo.

  • GD6100D Insulation Oil Tan Delta Tester

    GD6100D Insulation Oil Tan Delta Tester

    Muyedzo yekudzivirira yekuvharisa midziyo yemagetsi, nguva nenguva kuyerwa kweinodzivirira mafuta paramita yemidziyo yemagetsi inodiwa.Kuyerwa kwekurasikirwa kwedielectric uye resistivity yemafuta ekuvharisa ndechimwe chezvinhu zvakakosha.Kwenguva yakareba, vazhinji vavo vakayerwa nenzira yebhiriji, iyo yakaoma kushanda, uye kuyerwa kwechiyero kunokanganiswa nezvinhu zvakawanda, zvichikonzera kukanganisa kukuru kwechiyero..

     

  • HV-OWS-63 Oscillating Wave Test System (OWTS) yePasaiti PD Diagnostics yeCables.

    HV-OWS-63 Oscillating Wave Test System (OWTS) yePasaiti PD Diagnostics yeCables.

    HV-OWS-63 Oscillating Wave Test System (OWTS) yeOn-saiti PD Diagnostics ye10kV Cables inzvimbo yakabatanidzwa yekuburitsa chikamu uye manejimendi system.Yedza frequency inosiyana kubva pa50Hz kusvika kumazana eHertz pasi pekunyorovesa AC voltage.

    Iyo inoteedzera mamiriro ekumhanya kwetambo nekushandisa voltage, uye inogona kukonzeresa kuburitsa zvishoma uye kuona kusimba kwayo nenzvimbo.Iyo inoshandisa hollow inductor munhevedzano netambo yakaedzwa, uye inochaja yayo nhevedzano wedunhu kuburikidza neakakwira-voltage DC sosi.Kana magetsi ekuchaja asvika pamutengo we preset, inovhara ma switch emagetsi akabatana pamativi ese emagetsi sosi, nekudaro ichigadzira inonyorovesa oscillation circuit, ichigadzira oscillating voltage, uye iyi oscillating voltage inoshandiswa kufadza kubuda kwechidimbu pamhepo. kukanganisa kukanganisa kwetambo, uye kunaka kwetambo yekudzivirira kunogona kutongwa nekuona kubuda kwechidimbu.

     

     

  • GDW-106 Oiri Dew Point Tester

    GDW-106 Oiri Dew Point Tester

    Nguva yewaranti yeiyi nhevedzano IMWE gore kubva pazuva rekutumira, ndapota tarisa kune yako invoice kana magwaro ekutumira kuti uone akakodzera mazuva ewaranti.HVHIPOT corporation waranti kumutengi wekutanga kuti chigadzirwa ichi hachizove chisina hurema muzvinhu uye magadzirirwo pasi pekushandiswa kwakajairwa.

  • GDQH-31W Inotakurika SF6 Gasi Recovery Device

    GDQH-31W Inotakurika SF6 Gasi Recovery Device

    GDQH-31W Inotakurika SF6 Gasi Recovery Device (MINI) inoshandiswa mukugadzira chirimwa cheSF6 gasi insulated magetsi emidziyo uye kushanda & madhipatimendi ekutsvagisa sainzi kuzadza michina yemagetsi neSF6 gasi uye kudzoreredza SF6 gasi kubva kumidziyo yemagetsi yakashandiswa kana kuedzwa.

    Panguva imwecheteyo, inonatswa uye inomanikidzwa uye inochengetwa mutangi yekuchengetedza.Inokodzera ring network yekugovera network pazasi 50kV.

      

     

     

     

  • GDYD-A AC Hipot Test Set neAutomatic Control Unit

    GDYD-A AC Hipot Test Set neAutomatic Control Unit

    AC hi-pot yekuyedza ndiyo inoshanda uye yakatwasuka nzira yekuyedza kusimba kwesimba remidziyo yemagetsi, zvishandiso kana michina.Inotarisa kukanganisa kune ngozi iyo inovimbisa midziyo yemagetsi inoramba ichishanda.

    Zvishandiso zvakajairika zvinosanganisira kuyedzwa kwema transformer, switchgear, tambo, capacitor, aerial motors mapuratifomu, zvinopisa zvidhinha zvidhinha, mabhodhoro evacuum uye zvimwe zvine chekuita nazvo senge vacuum interrupters, magumbeze, tambo, magurovhosi, hydraulics hose, zviridzwa zvinoshandura jenareta.

     

     

  • GDHG-106B CT/PT Analyzer

    GDHG-106B CT/PT Analyzer

    GDHG-106B chishandiso chinoshanda chakanyanya kugadzirirwa kuongorora ikozvino ma transformer uye magetsi emagetsi ekudzivirira kana kuyerwa kushandiswa.Mushandi anongoda kuseta kukosha kweyedzo ikozvino uye voltage, chiridzwa chinozosimudzira voltage uye chazvino, uye chobva charatidza mhinduro munguva pfupi.Yedza data inogona kuchengetwa, kudhindwa, uye kurodha kuPC kuburikidza ne USB interface.

  • GDWG-IV SF6 Gasi Leak Detector(IR Series)

    GDWG-IV SF6 Gasi Leak Detector(IR Series)

    GDWG-IV SF6Gasi Leak Detector is infrared red type leak detector (NDIR tekinoroji).Iri ruvara OLED kuratidza uye chaiyo-nguva inoratidza SF6 kutariswa.

  • GDWG-V SF6 Gasi Leak Detector (rudzi rweIR, Kuratidzwa kaviri)

    GDWG-V SF6 Gasi Leak Detector (rudzi rweIR, Kuratidzwa kaviri)

    GDWG-V SF6 Gasi Leak Detector infrared red type leak detector (NDIR tekinoroji) ine kaviri kuratidzwa.Iro ruvara INCELL TFT kuratidza uye chaiyo-nguva inoratidza SF6 kusungwa.

  • GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer

    GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer

    Parizvino, iyo UHV voltage level ye110KV uye pamusoro inoshandisa SF6 gasi-yakavharirwa GIS sechinhu chikuru chemidziyo yechiteshi, kuongororwa kweGIS yemukati yekuvharisa mamiriro anowanikwa zvakanyanya nechikamu chekubuda kwekuona nzira uye SF6 gasi yekuongorora makemikari nzira kumba. uye kunze.

  • GDSF-411CPD SF6 Gasi Yakazara Analyzer

    GDSF-411CPD SF6 Gasi Yakazara Analyzer

    GDSF-411CPD SF6gasi comprehensive analyzer chinhu chinotakurika chakagadzirirwa kuyera SF6gas dovi point, kuchena uye kuora chigadzirwa.

  • GDSF-311WPD 3-In-1 SF6 Gasi Analyzer

    GDSF-311WPD 3-In-1 SF6 Gasi Analyzer

    GDSF-311WPD (GDSF-411WPD) chiridzwa chakanakira pazvinenge zvakakodzera kuyedza zvirimo mumvura, kuchena uye kuora zvigadzirwa zveSF6 gasi.Iyo yakakosha chikamu chedova point test ndeye DRYCAP® inoteedzera sensors inogadzirwa neFinland Vaisala kambani.

Tumira meseji yako kwatiri:

Nyora meseji yako pano uye titumire kwatiri