GDYM-3F Inotakurika Multi-inoshanda Energy Meter Calibrator
●Synchronously kuverenga ese maparamendi uye kuratidzwa pane iyo interface inosanganisira yakazara wave, yakakosha wave uye harmonic wave senge panguva imwechete inoratidza U, I, P, Q, VA, chikamu chekona nezve yakazara wave uye yakakosha wave pamwe neiyo harmonic synthesis yeI, U, P, Q, VA uye chikamu chayo, zviri mukati U, I positive sequence, negative sequence, zero sequence uye harmonics yePH+, PH-, PH+/Pf%, PH-/Pf%, full wave PF, basic wave PF, harmonic wave PF.
●Nzira yekuongorora inosanganisira 7 marudzi enzira dzeazere wave inoshanda, yakazara wave reactive simba, yakazara wave inooneka, yakakosha wave inoshanda, yakakosha wave reactive simba, yakakosha wave inooneka uye harmonic wave, iyo inogona kutarisa rinoshanda simba kurongeka kwemamita akazara wave, yakakosha. mita, harmonic wave mita uye iro reactive simba kurongeka kweazere wave uye harmonic wave mita, zvakare inogona kutarisa iko kuoneka kwemagetsi simba mita.
●Sarudzo inopokana imwe kana yakawanda harmonic kuverenga iyo harmonic musanganiswa weU, I, P, Q, VA uye chikamu chayo pamwe neharmonic wave inoshanda simba remagetsi.
●Panguva imwecheteyo chikamu chekuongorora chimwe chete uye kukosha kwekuyera kwega yega U, I, P, Q, VA yezvikamu zvitatu-chikamu harmonic wave uye kuratidza yayo 51 nguva + PH/-PH uye muzana yeyakakosha wave kuona pesvedzero yezvakanaka uye zvisina kunaka harmonic pane metering.
●Yakazara wave reactive simba ndiyo algebraic sum yesimba rinoshanda reiyo yakakosha wave uye harmonic wave yega yega harmonic.Kuti udzivise 90 dhigirii chikamu chekuchinja munguva yakapfuura uye mune iyo harmonic wave reactive simba rekuyedza kukanganisa.Isu tinokwanisa kuyera rudzi nemagetsi emagetsi emagetsi meter anogona kuwonekwa uye kusarudza nhamba yega yega harmonic wave.
●Panguva imwe chete edzai maviri akaonekwa pulse, uye inogara, inoshanda maitiro uye nhamba yeanoonekwa mapurusi panguva imwe chete anogona kunge akasiyana zvachose.
●Kuremedza 2.4 nguva, ese mapoinzi ekuyera anogona kuve nechokwadi chekuti chokwadi che0.05% uye zvakare akavimbisa iyo chiyero index yeCT yechipiri yakayerwa ikozvino kana iri 1A.
●500 nguva dzazvino renji inovimbisa kuyerwa indekisi, 1000 nguva yazvino kuratidza renji, iyo shoma ye1mA kutanga ikozvino.Panguva imwechete ye-high-voltage power supply, high-voltage device inoyerwa, uye wiring inogona kuonekwa pasina-mutoro.
●Electric energy accumulation function inogona kuyera electric energy mita iyo isina pulse kubuda.
●Ratidza vector diagram, inokwanisa kuona matatu-waya e48 isiriyo wiring uye ina-waya dze96 dzisiridzo wiring pamwe neCT yechipiri muchinjiko wiring.
●Adopt 7 inch 16: 9 giredhi giredhi uye hupamhi ruvara chidzitiro cheTFT, yega yega parameter yechiridzwa yakananga uye yakajeka kuratidzwa pachiratidziro panguva imwe chete pasina kutendeuka chidzitiro, bvumira vashandisi kushandisa nekungotarisa.
●Chiridzwa chinogona kutevedzera zvakasiyana-siyana zvechiitiko wiring uye kuwana mhedzisiro inowirirana yewaya uye kugadzirisa coefficient muhofisi pasina kuwana voltage kana chiratidzo chazvino.Iri basa rinogona kushandiswa sechishandiso chekudzidzira mitsara yekuongorora kuvandudza hunyanzvi hwekutarisa mutsara wevashandi vemumunda.
●Chiridzwa chemukati chinogona kuburitsa iyo chaiyo yazvino chiratidzo che 0.05-5A uye yakawedzerwa mu5A chivharo chekutarisa kukanganisa kwe clamp mita.Kufunga muaccount 5A clamp ine kukanganisa shanduko dambudziko mushure mekushandiswa kwenguva yakareba.Ita kuti urambe uchiziva mamiriro ekuvhara pamusoro pemamita ekusungirira chero nguva, yeuchidza vashandi vakakodzera nenguva kuchenesa shaya yekusunga.Kana uchitsiva iyo 5A clamp, iko kukanganisa kunogona kugadziriswa kusvika 0.2.
●Isa otomatiki nhamba yemamita emagetsi (inosarudza basa)
Tsigira barcode scanner uye inoisa otomatiki simba mita kodhi.
●Shandisa 485 kana infrared photoelectric musoro kuti uverenge iyo yakawanda-inoshanda simba mita tip, peak, flat, mupata, yakazara inoshanda uye inoshanda base, verenga nguva dzose uye nguva.Tsigira nyika chiyero DL645 mitemo, DL645-1997 uye DL645-2007.(sarudzo)
●Yakavakwa-mukati 2G yemagetsi dhisiki.
●Inogona kuve ne 3-inch field printer, ine bhatiri-powered, uye inoshandura zvakananga mufananidzo weruvara rweruvara kuita dema nechena paunenge uchidhinda. (optional)
●Kushandisa iyo clamp mita (5A, 100A, 500A, 1000A) zvakananga kuyera reshiyo uye reshiyo kukanganisa kweiyo low voltage current transformer.(100A, 500A, 1000A chisungiso chiripo)
●Ratidza voltage uye ikozvino waveform yezvikamu zvitatu A, B, C.
●Simba rekushandisa rekuisa renji ndeye 55V-600V.Iyo yakajairwa matatu-phase voltage yekupinda maindasitiri socket ndeye 600V.Industrial switching switching yekubatanidza guta remagetsi uye matatu phase voltage sesimba rebasa.
●Ese ma paramita anoda kuiswa pasaiti uye kurodha data anogona kutsanangurwa zvakasununguka nemushandisi.Inogona kudhawunirodha data ye5000 vashandisi.
●Chidzitiro chazvino chinogona kuchengetwa kuU disk.
●Iine tembiricha uye humidity kuyerwa basa (inoda kuisa tembiricha uye humidity sensor).
●Iine USB interface uye inobatanidza kune USB flash drive kugadzira nzvimbo yakakura yekukopa data.
●Bata chidzitiro uye wodzvanya kiyi oparesheni, iyo keyboard uchishandisa komputa kiibhodhi koramu kuronga.Iyo PC keyboard ine USB interface inowanikwawo.
●Nguva nePC muchina ne USB interface.
●Iyo komputa yepiritsi inogona kudzora zvakananga chiridzwa chine yakafanana yekushandisa interface sechiridzwa.
●Voltage kuyerwa socket uye simba switching switch yeindasitiri giredhi inogona kushandiswa pasi pe600V (Iyo yakajairwa utility simba switch ndeye 250V, iyo inoshandiswa mupamusoro-renji pa380V, ine njodzi dzinogona kuitika).
●Yakakwirira kuchengetedza dhizaini.Iyo mains socket, voltage yekuyeresa socket, yazvino kupinza, ikozvino clamp yekuisa yakaparadzaniswa, uye inomira voltage i4kV.
●Electric energy pulse input protection.Kana yaisa yakakwira voltage inongotanga kudzivirira uye kuratidza kukurumidza meseji pane chiridzwa, kana kukanganisa kwagadziriswa, tinya pane interface kuti uisezve dziviriro.
●Iyo 5A clamp ine yega yekuzvigadzirisa basa: iyo 5A's ikozvino siginecha inogadzirwa mukati nechombo chakawedzerwa kune 5A clamp kuyera kukanganisa kwemamita ekurovera.
●5 yakaderera simba ARM machipisi anoshandiswa, kugona kwese kuverenga kwakakura kupfuura 1GIPS, uye ese ma paramita e51 harmonic uye yakazara wave inoverengerwa panguva imwe chete.
●Uchishandisa Windows CE oparesheni system ine yakakura uye yechokwadi, basa rayo rakagadzikana uye rakavimbika.
Voltage | Guarantee kukanganisa range | 25-600V | |||
Kutanga kuyera kukosha | 0.5V | ||||
Rated value | 440V | ||||
Kukanganisa kwechokwadi | ±0.05% | ||||
Current | Terminal | RatedIe | 5A | ||
Range | 0.025A-12A | ||||
Clamp | RatedIe | 5A, 100A, 500A,1000A(sarudzo) | |||
Range | 0.5%Ie—2.4Ie | ||||
Kutanga ikozvino | 0.02%Ie | ||||
Input frequency range | 45-65Hz | ||||
Frequency kuyera kukanganisa | ±0.01Hz | ||||
Phase angle measuring range | -180°- 180° | ||||
Max.Phase angle error | ±0.1° | ||||
Harmonic percentage, harmonic magetsi parameters, uye harmonic magetsi emagetsi ekuyera nguva | 2-51nguva | ||||
Pulse constant (Cherechedza:Ieyakayerwa ikozvino) | Low frequency output(3 magiya) | 5A | 3600P, 36000P, 360000P/kWh(kvarh, kVAh) | ||
vamwe | 3600P, 36000P, 360000P *(5/Ie)P/kWh (kvar, kVAh) | ||||
Internal high frequency | 5A | 1.8x109P/kWh | |||
Mamwe magiya azvino | 1.8x109*(5/Ie)P/kWh | ||||
Maximum pulse input frequency | 50kHz | ||||
5Aterminal | Full-wave basic wavekWh, P, U, I | ±0.05% | |||
Full-wave basic wave Kvarh, Q, VA, VAh | ±0.2% | ||||
HarmonicwaveU, I, P, Q, S | ±0.2%H(H=1+0.01k K=2-51) | ||||
5Aclamp | Full-wave basic wavekWh, P, U, I | ±0.2% | |||
Full-wave basic wave Kvarh, Q, VA, VAh | ±0.2% | ||||
HarmonicwaveU, I, P, Q, S | ±0.5% H(H=1+0.01k K=2-51) | ||||
Kuzvitarisa ikozvino cyclic kubuda ikozvino | 0.05A, 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A | ||||
Selfcheckingkukanganisa (mutsara uye angular musiyano) | ±0.1% | ||||
Big current clamp | Full-wave basic wavekWh, P, U, I | ±0.5% | |||
Full-wave basic wave Kvarh, Q, VA, VAh | ±0.5% | ||||
HarmonicwaveU, I, P, Q, S | ±1.0% H(H=1+0.01k K=2-51) | ||||
Vamwe | Reshiyo kuyerwa | ±0.5% | |||
Voltage pesvedzero | <±0.01% | ||||
Frequencypesvedzero | <±0.01% | ||||
Tembirichapesvedzero | <±0.005%/℃ | ||||
24hours kuchinja kukanganisa | <±0.01% | ||||
Harmonicpesvedzero | <±0.01% | ||||
Rechargeable bhatiri | 11.1V 3000mAh | ||||
Kumira magetsi (Voltage ikozvino kuyerwa uye magetsi ekupa uye yakaderera-voltage terminals) | 4.0 kV | ||||
Magetsi Anokurumidza Kupfuura Kuputika | 4.0 kV | ||||
Surge | 4.0kV(Common mode),2.0kV(Differential mode) | ||||
Nguva yekumira mushure mekutanga | <3Mineti | ||||
Ambient tembiricha | -25 ℃-+45 ℃ | ||||
Hunyoro hwehukama | 40% -95% | ||||
Kushanda magetsi | AC 55V - 600V | ||||
Simba rekushandisa | <9W | ||||
Dimension | 275mm * 196mm * 78mm | ||||
Kurema | <1.5 kg |
1--Bata skrini
2--Process bar
3--Delete kiyi
4--Kubuda (kumashure) kiyi
5--Kiyibhodhi
6--Chinja kiyi
7--Space kiyi
8--Kufamba/OK kiyi
9--Simba remagetsi
10--Simba yemagetsi
11--Three phase voltage input socket (ABC)
12--USB chiteshi
13--RS232 interface yekugadzirisa chiteshi
14--Socket yekuchaja
15--Battery switch
17--Seven core wiring hold for A phase current clamp
18--Seven core wiring hold for B phase current clamp
19--Seven core wiring hold for C phase current clamp
20--Pulse signal interface
21--Chikamu chazvino chekuisa & socket yekubuda
22--B chikamu chazvino chekuisa & yakabuda socket
23--C chikamu chazvino chekuisa & yakabuda socket
24--Bupe rekurembera
Munda calibrator yemamita matatu chikamu watt awa mita | 1 set |
100A clamp Watch | 3 zvidimbu |
Mhete yekugadzirisa clamp | 1 chidimbu |
Photoelectric musoro df307 | 1 chidimbu |
USB dhisiki (management software) | 1 chidimbu |
3 phase voltage line high voltage (kusanganisira clamp uye pini) | 1 chidimbu |
3 chikamu chazvino mutsara (kusanganisira clamp uye kuisa) | 1 chidimbu |
3 chikamu pulse mutsetse 1A | 1 chidimbu |
Adapter | 1 chidimbu |
Tambo yemagetsi | 1 chidimbu |
Straps | 1 chidimbu |
Bhokisi rezviridzwa | 1 chidimbu |
Product manual | 1 kopi |
Product certificate | 1 kopi |
Factory packing list | 1 kopi |
Factory test report | 1 kopi |