GDSF-311WPD 3-In-1 SF6 Gasi Analyzer
GDSF-311WPD (GDSF-411WPD) chiridzwa chakanakira pazvinenge zvakakodzera kuyedza zvirimo mumvura, kuchena uye kuora zvigadzirwa zveSF6 gasi.Iyo yakakosha chikamu chedova point test ndeye DRYCAP® inoteedzera sensors inogadzirwa neFinland Vaisala kambani.Iyo infrared musimboti SF6 gasi kuchena yekuyedza sensor inogadzirwa neEuropean Sensor Kambani inoshandiswa kuyedza kuchena kweSF6 gasi.Iyo electrochemical sensor inogadzirwa neMombabo Kambani kuSwitzerland inoshandiswa sechinhu chinonzwa chekuyedza zvigadzirwa zveSF6 gasi rekuora.Nehunyanzvi hardware machipisi uye yakanakisa software algorithms yeSTMicroelectronics, takagadzira chizvarwa chitsva che3-in-1 gasi analyzer.
SF6Humidity
●Kuyera nzira: Resistive uye Capacitive kuyerwa musimboti
●Chiyero chekuyeresa: dova point -80 ℃--+20 ℃ (rutsigiro ppmv)
●Kururama: ±1℃
(kana tembiricha yedova iri pazasi 0 ℃, iyo sensor inobuda ndiyo nzvimbo yechando)
●Nguva yekupindura: 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
●Kugadzirisa: 0.01 ℃
●Kudzokorora: ± 0.5 ℃
●Ratidza unit: ℃, ppm, ℃P20 (yakashandurwa kukosha pa20 ℃)
●Kuyerera kwegesi: 400-600ml / min
●Kuyerera kuratidzwa: 0-1000mL digitaalinen kuyerera mita
●Sample gasi pressure: ≤1MPa
SF6Kuchena
●Nzira yekuyera: Infrared Measurement Principle (NDIR series sensors)
●Kuyera huwandu: 0 ~ 100% SF6
●Nguva yekupindura: [90%] 60s
●Kunyatsoita: ± 0.5%FS
●Kudzokorora: ± 0.5%
●Mhedziso: 0.01%
●Ratidza chikwata: %
SF6Decomposition Products
●Nzira yekuyera: Electrochemical Measurements Principle (Electrochemical series sensors)
●Chiyero chiyero: H2S: 0 ~ 200ppmv
SO2: 0 ~ 200ppmv
CO: 0 ~ 500ppmv
HF: 0 ~ 50ppmv
●Kururama: H2S: 10ppmv ± 3%
SO2: 10ppmv ± 3%
CO: 50ppmv ±4%
HF: 10ppmv ±3%
●Kudzokorora: H2S: 10ppmv ± 2%
SO2: 10ppmv ± 2%
CO: 50ppmv ±2%
HF: 10ppmv ±2%
●Chisarudzo: 0.01ppmv
●Ratidza unit: ppmv
●Simba rekushandisa: 220VAC ± 10%, 50Hz, AC/DC kushandiswa, kuchengetedzwa kwepamusoro-chaji, kuenderera mberi kwekushanda hakuna kuderera pane 8hours.
●Shandisa nharaunda tembiricha: -20--+60 ℃
●Kunyorova kwenzvimbo: 90% RH
●Kuyera kukosha kwesimba: Hapana mhedzisiro yekumanikidza uye kuyerera
●Kuyera: 395 * 295 * 155mm
●Kurema: anenge 2kg.
GDSF-411WPD SF6Decomposition Products
●Kururama: H2S: <10ppmv ±0.3ppmv;>10ppmv ±3%
SO2: <10ppmv ±0.3PPmv;>10ppmv ±3%
●Kudzokorora: H2S: <10ppmv ± 0.2ppmv;>10ppmv ±2%
SO2: <10ppmv ±0.2PPmv;>10ppmv ±2%
●Kudzokorodza uye kuzadza basa: recycling kamuri 2L,kudzokorodza nguva ≤ 5min
Nekuomesa gasi basa
●Dimension: 395*295*315mm
●Kurema: anenge 5kg.
Main Tester | 1 chidimbu |
Adapter | 1 set |
Teflon pombi (inosanganisira kuyerera kwevharuvhu uye nekukurumidza chinongedzo) | 1 set |
Muswe pombi | 1 set |
Spare parts | 1 set |
Charger | 1 chidimbu |
Mushandisi's Guide | 1 chidimbu |
Test Report | 1 chidimbu |