GDOT-80C Insulation Oil Breakdown Tester 80kV
Kune huwandu hukuru hwemidziyo yemagetsi mumagetsi sisitimu, njanji system uye yakakura petrochemical plant migodhi nemabhizinesi, yavo yemukati yekuisa mukati kazhinji inozadzwa nemafuta.Iyo dielectric simba re insulating oiri ndeye inosungirwa muitiro bvunzo.Kuitira kuzadzisa zvinodikanwa zvemusika, kambani yedu yakagadzira uye yakagadzira akateedzana dielectric mafuta dielectric simba testers zvinoenderana neIEC156 yakajairwa "Insulating mafuta-kutemerwa kwesimba re dielectric" uye yenyika indasitiri standard DL-474 · 4-92DL/T596. -1996"Kudzivirira bvunzo kodhi yemagetsi emagetsi emagetsi".
Ichi chiridzwa chinotora iyo single-chip microcomputer seyo musimboti, inoona otomatiki yese yebvunzo, ine yakakwirira kuyerwa kwechiyero, inovandudza zvakanyanya kushanda zvakanaka, uye inoderedza zvakanyanya kuwanda kwevashandi.Panguva imwecheteyo, chiridzwa chine compact chitarisiko uye chiri nyore kutakura.
●Iyo inotora microprocessor kuti ipedze otomatiki mashandiro ekusimudzira, kubata, kubvongodza, static, kuverenga, kudhinda, nezvimwewo, uye inogona kuita kutenderera kweoiri kumirisana nevoltage test muhuwandu hwe0-80 kV.
●Mukombe wemafuta wechiridzwa unoumbwa nekamwe-nguva kukanda kwegirazi yakakosha, iyo inodzivirira kupindira kwakadai sekudonha kwemafuta.
●Iyo yakasarudzika yepamusoro-padivi sampling dhizaini yechiridzwa inobvumira kukosha kwekuyedza kupinda muA / D inoshandura zvakananga, kudzivirira zvikanganiso zvakakonzerwa mudunhu reanalog, uye kuita kuti kuyerwa kuwedzere kuve kwakanyatso.
●Zviridzwa bvunzo dzekuita zviyero zvinosanganisira indasitiri zviyero, zviyero zvenyika uye zvekunze zviyero, uye kushanda kuri nyore uye kuri nyore.
●Ne-over-voltage, over-current, limit uye kumwe kudzivirira kuve nechokwadi chekuchengetedzwa kwevashandisi.Uye ine yakasimba anti-kupindira kugona uye yakanaka electromagnetic kuenderana.
●Output voltage: 0-80kV
●Mwero wekukanganisa simba: <1%
●Kukwanisa: 1.5kVA
●Kapu yemafuta: 240ml
●Chiyero chechokwadi: ± 3%
●Voltage inowedzeramwero: 2kV/s, 3kV/s sarudzo, kukanganisa: 0.2kV/s
●Simba rekuisa: AC220V± 20%, 50Hz±5Hz
●Simba: <200W
●Kushanda tembiricha: 0-40 ℃
●Humidity: <85%RH
●Dimension: 430*350*370mm
GDOT-80C chiridzwa | 1 chidimbu |
Kapu yemafuta (250ml) | 1 chidimbu |
Tambo yemagetsi | 1 chidimbu |
Ground cable | 1 chidimbu |
Spare fuse | 2 chidimbu |
Kukurudzira nzungu | 2 chidimbu |
Standard 2.5mm | 1 chidimbu |
Tweezer | 1 chidimbu |
Prinda bepa | 1 rolls |
Gwaro remushandisi | 1 kopi |
Factory test report | 1 kopi |
Imwe electrode inosarudzwa