●Yakazara basa uye inogona kugutsa marudzi ese eCT (kudzivirira CT, kuyera CT, TP) bvunzo zvinodiwa, senge excitation characteristic test, turn ratio, polarity, second winding resistance, second burden, ratio error, angular difference and etc. Uyewo inogona kushandiswa kuyedza hunhu hwekusimudzira, kutendeuka reshiyo, polarity, yechipiri mhepo kuramba, reshiyo kukanganisa, angular musiyano uye nezvimwe zvemarudzi ese ePT.
●Kuongororwa kwemumunda kweCT hakudi akajairwa azvino anoshandura, injector yazvino, bhangi rekutakura, voltage regulating controller uye tambo huru dzazvino.Yakareruka kwazvo bvunzo wiring uye mashandiro anoshandiswa kuona iyo yazvino transformer verification, iyo inoderedza zvakanyanya kusimba kwebasa uye inonatsiridza mashandiro ebasa, uye kufambisa kuoneswa kwemunda kwevashanduri.
●Nyatsoyera kukanganiswa kwereshiyo uye musiyano weangular, iyo yakanyanya kubvumidzwa kukanganisa kwereshiyo kukanganisa ndeye ± 0.05%, uye iyo yakanyanya kubvumidzwa kukanganisa kweangular musiyano ndeye ± 2min.Inogona kuyera iyo 0.2S level ikozvino transformer, uye reshiyo kuyerwa renji i1 ~ 40000.
●Zvichienderana neiyo yepamusoro frequency yekushandura nzira yekuyedza CT/PT voltage-yazvino hunhu curve uye 10% kukanganisa curve, iyo yakanyanya AC voltage ye180V uye AC ikozvino ye12Arms (36A peak) inogona kubuda, asi inogona kubata neiyo CT bvunzo. yemabvi anonongedza kusvika ku60KV.
●Auto test CT/PT parameters senge ibvi point voltage/current, 5% uye 10% kukanganisa curve, accuracy limit factor (ALF), safety factor (FS), second time constants (Ts), magnetic remanence coefficient (Kr), yakazara. uye unsaturated inductance.
●Muedzo unosangana nemhando dzakasiyana-siyana dzeshanduro zviyero seGB1208 (IEC60044-1), GB16847 (IEC60044-6), uye GB1207, uye zviyero zvebvunzo zvinosarudzwa zvinoenderana nerudzi uye nhanho yeshanduko.
●Muedzo uri nyore uye wakanakira.CT DC kuramba, kuwedzeredza, chiyero uye polarity inogona kupedzwa nekiyi imwe.Kunze kwekuyedzwa kwemutoro, mamwe ese bvunzo dzeCT anotora yakafanana wiring mode.
●5.7-inch graphic transflective LCD, inonyatsooneka muzuva.
●Inoshandiswa neinotenderedza optical mouse, iko kushanda kuri nyore, nekukurumidza uye kuri nyore, uye kuri nyore kubata.
●Yakavakwa-mukati printer, inodhinda otomatiki iyo yakagadzirwa bvunzo mushumo.
●Mhedzisiro yebvunzo inogona kutumirwa kunze neU disk, uye chirongwa chinogona kukwidziridzwa neU disk, iri nyore uye nekukurumidza.
●Sevha 1000 mapoka data uye haina kurasika mushure mekudzika kwemagetsi.
●Iyo inoshongedzerwa neyekumashure yekuongorora software kuti ifambise kuchengetedza, kutendeuka uye ongororo yemishumo yebvunzo, uye inogona kushandiswa kuenzanisa, kutonga uye kuongorora yebvunzo data.
●Easy kutakura, mudziyo uremu <10kg.