GDFJ-VI Transformer Yakanyungudika Gasi Analyzer
GDFJ-VI Transformer Yakanyungudutswa Gasi Analyzer inotakurika gasi chromatograph yakakodzera pa-saiti kukurumidza kuongororwa.Inobatanidza chromatographic kuona, kuongorora uye kuongororwa mune imwe, pamwe neiyo micro detector, mini gasi sosi uye yakavakirwa-mukati yekubata screen komputa.Iine kubatanidzwa kwepamusoro, kugadzikana kuri nani, chimiro chakapfava uye kushanda kuri nyore kupfuura yechinyakare inotakurika oiri chromatography.Pa-saiti ongororo inogona kuongorora nenguva uye kuongorora shanduko yekuchinja mamiriro, kuita kuti simba rishande rive nyore uye nyore.Icho chiridzwa chinotora yekirasi matatu-detector process, uye data yekuongorora yakafanana neyechinyakare laboratory chromatograph.Iyo chiridzwa inotora yepamusoro diki modular dhizaini pfungwa.Iine kusanganiswa kwepamusoro, hukuru hudiki uye huremu huremu, izvo zviri nyore kutakura kunzvimbo yekuongorora.Inopa data rakakodzera uye rakakwana rekutarisa uye bvunzo yekushandura, uye inochengetedza akawanda manpower uye zviwanikwa zvezvinhu.
Ongororo yakazara yezviri mukati mezvikamu zvinomwe zvegasi H2, CO, CO2, CH4, C2H4, C2H6, C2H2(hydrogen, carbon monoxide, carbon dioxide, methane, ethylene, ethane, acetylene) yakanyungudutswa mumafuta anodzivirira anogona kupedzwa mune rimwe jekiseni.Iyo shoma yekuona kusangana kweacetylene ndeye 0.1ppm, uye yakashandiswa zvakabudirira kumaindasitiri mazhinji nemadhipatimendi akadai semakambani emagetsi emagetsi, zvidyarwa zvemagetsi, zvidyarwa zvetransformer, mabhizinesi makuru ekunyungudutsa, uye zvikamu zvemagetsi enjanji.
●Yakavakirwa-mukati yekubata-bata screen anti-control tekinoroji yekuona inoonekwa yezviridzwa mhepo yekumanikidza.
Yese mhepo yekumanikidza inoratidzwa nedhijitari neiyo pressure sensor.Kudzvanywa kweanotakura gasi, hydrogen gasi nemhepo zvinogona kuverengerwa zvakananga kuburikidza nenzvimbo yebasa, uye mamiriro ekuongorora anogona kubatwa munguva chaiyo.
●Kushandisa touch screen anti-control tekinoroji kuwana tembiricha yekumisikidza, kuratidza uye mamwe mashandiro.
Yese tembiricha paramita inogona kuratidzwa digitally.Iyo tembiricha yebhokisi bhokisi, detector uye reformer inogona kuverengerwa uye kudzorwa zvakananga neworkstation.Kuvhiya kuri nyore uye kwakajeka.
●Bata skrini tinya kuti upedze kupisa, kutonhora, kubatidza uye zvigadziriso zvazvino.
Yakavakwa-in otomatiki mhepo nzira yekudzora mudziyo inobvisa otomatiki chikamu chemhepo kana ichishanda pane yekubata sikirini, kuitira kuti reshiyo yehydrogen kusvika kumhepo isvike reshiyo yakakodzera kupisa, uye inodzoreredza reshiyo mushure mekunge kupisa kwapera otomatiki;zvimwe chetezvo, kuburikidza nebhiriji rekuyerera kuseta hwindo mune yekushanda software inogona kupedzisa kuseta kwekuyerera kwebhiriji kuyerera.
●Digital FID yemagetsi zero-setting tekinoroji yekusimudzira anti-kupindira kugona kwechiridzwa.
FID detector inoshandisa tekinoroji zero-setting tekinoroji uye yakakwirira-chaiyo dhijitari yedunhu kutsiva iyo yakakosha ikozvino yeFID, kuitira kuti ione mutemo wemagetsi weiyo inobuda chiratidzo cheiyo FID.Nekuti iyo yemagetsi regulation inogona kuiswa yakananga pane yechiratidzo chiteshi chebhodhi redunhu kuti ivandudze kugona kwemagetsi ruzha kudzvinyirira, hapana chiratidzo chekuvhiringidza kana mechanical potentiometer yakabatana.Nekuda kwekudzikisa parasitic parameter, ine yakasimba anti-kupindira kugona.
●Kushandisa komputa inopesana-kudzora tekinoroji kuwana kutonga kweiyo oscillator.
Kuburikidza nemutsara wechiratidzo chekubatanidza, inogona kupa simba kune diki oscillator, uye kuburikidza nenzvimbo yekushanda, inogona kushanda iyo yese maitiro eiyo oscillator, sekudziya kumusoro, kutanga oscillation, kumira, buzzing nekukurumidza kumagumo, etc.ystem in. Chirungu neChinese, iyo inogona kuchinjwa zvakasununguka.
●Yakavakirwa-mukati yakanyarara pombi yemhepo, isina kunze kwemhepo sosi.
Iine pombi shoma yemhepo inotengeswa mukati mejini huru, inogona kupa mhepo sosi yechiridzwa pasina kukanganiswa.Nekuda kwedhizaini-yekuvhundutsa, pombi yemhepo inogona kushanda chinyararire, uye mushandisi haazombonzwa kuvepo kwayo.
●Gasi breakage dziviriro basa re thermal conductive tungsten waya.
Iine hungwaru hwekudziya cutoff dziviriro basa, kana mutakuri gasi kudzvanywa kuri kushoma pane ekuchengetedza chikumbaridzo, sisitimu inozodzima iyo yekupisa conductivity yazvino kudzivirira iyo yekupisa conductivity detector kubva mukukuvara.
Chikamu | Min.kuona pfungwa |
H2 | 2 |
CO | 5 |
CO2 | 10 |
CH4 | 0.1 |
C2H4 | 0.1 |
C2H6 | 0.1 |
C2H2 | 0.1 |
FID (moto ionization detector)
●Muganho wekuona: Mt≤3 × 10-12g/s (Hexadecane/isooctane)
●Baseline ruzha: ≤5 × 10-14A
●Kuchinja kwekutanga: ≤1 × 10-13A / 30min
●Linear range: ≥ 106
TCD (thermal conductivity detector)
●Sensitivity: S≥3500mV•ml/mg (yakajairika);5000mV•ml/mg (yakanyanya kunzwa)
●Baseline ruzha: ≤10μV
●Baseline shift: ≤30μV/30min
●Linear range: ≥104
Temperature control index
Tembiricha yekudzora chikamu | Range | Kururama |
Column box | 4 ~ 450 ℃pamusoro pekushisa kwekamuri | ±0.1℃ |
Packed column injector | 4 ~ 450 ℃pamusoro pekushisa kwekamuri | ±0.1℃ |
FID Detector | 4 ~ 450 ℃pamusoro pekushisa kwekamuri | ±0.1℃ |
TCDDetector | 4 ~ 450 ℃pamusoro pekushisa kwekamuri | ±0.1℃ |
Nickel catalyst shandukoer | 4 ~ 450 ℃pamusoro pekushisa kwekamuri | ±0.1℃ |
Vamwe
Dimension: 420*280*300mm
Kurema: ˂15kg
Simba rekushandisa: AC220V ± 10%, 50Hz
Aihwa. | Zita | Tsanangudzo | Qty. |
1 | Inotakurika DGA | GDFJ-VI | 1set |
2 | Chromatography workstation | Insulating oiri yakakosha edition | 1set |
3 | Miniature Yakazara otomatiki Oscillator | 1set | |
4 | High Purity Nitrogen | 2L, 99.999%, Aluminium alloy bhodhoro | 2mabhodhoro |
5 | High Purity Hydrogen | 2L, 99.999%, Aluminium alloy bhodhoro | 1bhodhoro |
6 | Standard Gas | 2L, 7 Zvikamu, Aluminium alloy bhodhoro | 1bhodhoro |