GDCY-20B 20kV Impulse Voltage Tester (Basic Type)
GDCY-20B Programmable Automatic Impulse Voltage Tester inonyanya kubva paTB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, JB8/T 7 imwe chiyero uye JB3048 zvinodiwa.Inonyanya kushandiswa kuchengetedza kuita (dielectric performance) yekuona yakaderera-voltage magetsi midziyo, yakakwirira uye yakaderera voltage switch, solar simba, magetsi metres, relays, leakage dziviriro, etc. Iyo impulse inobuda inogona kudzorwa nekombuta, uye bvunzo. rondedzero inogona kudhindwa uye kugadzirwa.
●Manual / automatic / programmable mode: Manual mode inogadzirisa impulse voltage manually nekugadzirisa knob;Automatic mode inogadzirisa impulse voltage otomatiki nehurongwa;Programmable mode inoshandisa komputa kudzora impulse voltage otomatiki.
●Automatic modhi uye programmable modhi ine otomatiki inogara voltage system, iyo inogona kudzora impulse inobuda voltage zvakanyanya uye haina kukanganiswa nenguva yenguva.
●Programmable control function inopa 485 kutaurirana interface uye chirongwa chekudzora protocol.Programmable test system inogona kumisikidzwa zvinoenderana nezvinodiwa.Impulse voltage uye akasiyana ma parameter (programmable trigger) anogona kudzorwa nekombuta kana programmable network.
●Kuburikidza nekombuta chirongwa chekudzora software, batch musanganiswa wekuyedza unogona kuitika, senge 2KV3 nguva, 4KV3 nguva, 6KV3 nguva, -2KV3 nguva, -4KV3 nguva, -6KV3 nguva, nezvimwe. Mapoka makumi mashanu ekuedzwa kwemusanganiswa anogona kuitika, uye mhinduro dzebvunzo dzakaita senge nguva dzekuparara uye kuparara kwemagetsi zvinogona kudzoserwa pakombuta.Iyo komputa inogona kuratidza mhinduro mhinduro zvine graphic kuita kuti mutongo uwedzere kunzwisisika.
●Chirevo chebvunzo chinogona kudhindwa uye kugadzirwa nekombuta, uye iyo data yekuyedza senge peak kukosha, nhamba yekupusha uye nguva yepakati inogona kuratidzwa.
●Basa rekutonga otomatiki yemhedzisiro yebvunzo rinogona kungozvitongesa kuti bvunzo yacho inokodzera here kana kuti kwete zvinoenderana nehukuru uye attenuation dhigirii yekufungidzira ikozvino inogadzirwa panguva yekuyedzwa.
●Inopa impulse divider interface yeiyo oscilloscope yekutevera yakabuda voltage waveform uye yekutarisa inobuda voltage.
●128 * 64 LCD kuratidzwa, kuratidza DC voltage, impulse voltage, nguva yenguva, uye nhamba yekukurudzira.
●Bata mabhatani, PC control, Chirungu pani uye chirongwa menyu zviripo.
●Positive uye yakaipa polarity inogadzirwa neiviri system yeyakanaka high voltage sosi uye yakaipa yakakwira voltage sosi.Kubuda kwacho kunowedzera kugadzikana, magetsi akakwirira uye kushanda kwakakwirira.
●Yekutanga yakazara-scale calibration process, iyo yakazara renji kurongeka kuri nani.
●Yakavakwa-mune akawanda parameter akajairwa calibration maitiro, iko kukanganisa kunogona kugadziriswa chero nguva.
●DC uye impulse dual output.
●Output impulse peak voltage: 20kV (4kV-12kV), kunyatsoita: + 3%;
Yakananga kugadzika kwe impulse voltage range mune otomatiki modhi uye programmable mode: 4kV-20kV;
Nhanho Voltage: 1V;
●Impulse voltage waveform: wave pamberi penguva 1.2μs±30%;
wave hafu-yepamusoro nguva 50μs±20%;
●Kuputsa kutonga: kuvuza ikozvino: 30mA-1200mA inogona kuiswa;
voltage attenuation: 0-99% inogona kuiswa;
●Nguva yepakati: 1-9999S;
●Nhamba yekukurudzira: 1-9999 / kusingaperi kuenderera mberi;
●Polarity: Positive/Negative/Positive and Negative alternately set;
●Dimension: 450mm * 380mm * 240mm;
●Kurema: anenge 12 kg;
●Optional Extension System Tsigiro: WinXP Win7.
Impulse Voltage Tester: 1 chidimbu
Yakakwirira uye yakaderera voltage test cables: 1 set
Nhaurirano tambo ye485-USB inoshandura: 1 chidimbu
DB9 Serial port yekuwedzera tambo: 1 chidimbu
Basic control system software: 1 set