GDBR-P Transformer Load Hapana-mutoro uye Capacity Tester
●Kuyera transformer Kwete-mutoro ikozvino, Hapana-mutoro kurasikirwa, pfupi redunhu voltage, kupfupika kwedunhu kurasikirwa uye kugona.
●Nzira dzekuedza mamita matatu.
●Paunenge uchigadzira matatu phase transformer No-load, mutoro bvunzo, chiridzwa chinotonga kana wiring yakaringana otomatiki, uye inoratidza matatu nhanho voltage, ikozvino vector dhizaini.
●Pedzisa mutoro bvunzo pasi pe1600kVA pazasi kugovera transformer izere ikozvino kune imwechete muchina.Pedzisa 2500kVA pazasi yekugovera dhizaini bvunzo pasi pe 1/3 yakayerwa ikozvino (Pasi pe1/3 yakayerwa ikozvino, chiridzwa chinogona kushandurwa kuti chitakure kurasikirwa paramita pasi peyakayerwa ikozvino.)
●Yese mibairo yebvunzo inogadziriswa yega.Chiridzwa otomatiki kururamisa sezvinotevera, waveform kururamisa, kururamisa tembiricha, Non rated voltage kururamisa uye isina rated ikozvino kururamiswa.Mhinduro dzebvunzo dzakanyanya kunaka.
●320 * 240 yakakwirira kupenya LCD skrini, ine kupenya kugadzirisa.Bata mabhatani anoita kuti kushanda kuve nyore.
●Chaiyo-nguva wachi, yekurekodha zuva rekuyedza otomatiki, yakakodzera kuchengetedza uye manejimendi emhedzisiro yebvunzo.
●Yakavakwa-mukati-paneru-mhando yemafuta printer, inokurumidza kudhinda mhinduro dzebvunzo.
●Simba pasi chitoro uye tarisa data (yedzo chinhu seti, kuyerwa mhinduro, nguva yekuyedza) mabasa.Chengetedza kusvika ku500groups bvunzo mhinduro, data transmission online kuPC.
●Inobvumira kureba kweyero yekunze voltage transformer uye yazvino transformer.Kuyera bvunzo chinhu chero parameters.
1. Test zvinhu
●RMS yezvikamu zvitatu zvemagetsi: Uab, Ubc, Uca.
●Avhareji kukosha kwezvikamu zvitatu AC voltage: Uab, Ubc, Uca.
●RMS yezvikamu zvitatu zvazvino: Ia, Ib, Ic.
●Percentage yeNo-load kurasikirwa uye No-load current: Po, Io%.
●Kurasikirwa nemutoro, impedance voltage percentage, short circuit impedance: Pt, ekt, Zt.
●Kurasikirwa nemutoro, impedance voltage percentage uye short circuit impedance pane chero tembiricha yakatarwa.
●Transformer chaiyo kugona uye inotongwa kugona.
2. Main michina parameters
●Ikozvino kuyerwa kwechiyero: 100mA-60A, kunyatsoita: kirasi 0.2.
●Voltage kuyerwa kwemhando: 10V-650V, kunyatsoita: kirasi 0.2.
●Transformer yekunze inogona kuwedzera kuyerwa kwechiridzwa.
●Frequency kuyerwa kwemhando: 40-65Hz, kunyatsoita: kirasi 0.2.
●Kupinza kwesimba: AC220V± 10%.
Main Unit | 1 pc |
Tambo yemagetsi | 1 pc |
Climp yekuyedza tambo | 1 set |
Special short-circuit cable | 1 pc |
Gwaro remushandisi | 1 pc |
Factory test report | 1 pc |