GD6900 Capacitance uye Dissipation Factor Tester
GD6900 inoyera capacitance uye dielectric kurasikirwa chinhu (tgδ) yemhando yepamusoro yemagetsi emagetsi.Iyo yakabatanidzwa chimiro, yakavakirwa-mukati dielectric kurasikirwa bvunzo bhiriji, inoshanduka frequency inogadziriswa magetsi, inosimudzira transformer uye SF6 yakajairwa capacitor.
Yakakwira voltage sosi inogadzirwa nemukati inverter yechiridzwa, iyo inoshandiswa kuyedza chinhu chekuyedza mushure mekuwedzera kwekushandura.Kana ukawedzera kapu yekudzivirira uye tembiricha yekudzora mudziyo, dielectric kurasikirwa kwemafuta anodzivirira anogona kuyedzwa.
●Bata LCD skrini inoratidza.
●Insulation kuramba kuyerwa: Yakavakwa-in insulation kuramba bvunzo module, inogona kuita Insulation kuramba (IR), absorption ratio (DAR), polarization index (PI) bvunzo.
●Calendar chip uye hombe yekuchengetedza mukati.Sevha mhinduro yekuyedza zvinoenderana nenguva yekuraira, tarisa rekodhi rekodhi uye dhinda mhedzisiro.
●Iyo data yemidziyo inogona kutumirwa kunze kuburikidza neU disk.
●Multiple test mode, ine modhi yemukati yakakwira voltage, kunze yakakwira voltage, yemukati mwero, yekunze mwero, GST/UST, kuzvifadza.Yakakwira voltage (kupfuura 10kV) dielectric kurasikirwa bvunzo inogona kuitwa mumamiriro ekunze chiyero kunze kwakakwira voltage.
●Edzai yakazara yakavharwa CVT (Capacitive Voltage Transformer) C1 uye C2 dielectric kurasikirwa uye capacitance panguva imwe chete.Edzawo CVT shanduko chiyero uye voltage angle musiyano.
●Iyo dielectric kurasikirwa uye capacitance kukosha kweC0 mumucheto wepamusoro weCVT inogona kuyerwa nekushandisa reverse shielding nzira.
●High speed sampling chiratidzo.Inverter uye sampling wedunhu mukati anodzorwa digitized.Output voltage inogadziriswa nguva dzose.
●LCR otomatiki kuyerwa.Inductance, capacitance, kuramba, kona inogona kuyerwa uye kuratidzwa.
●Multiple dziviriro yekupinza voltage fluctuation, yakabuda pfupi dunhu, yakawandisa-voltage, pamusoro-ikozvino, tembiricha, yakachengeteka uye yakavimbika.Zvichakadaro, ine basa rekuyedza pasi, iyo voltage boost haitenderwe kune isiri-grounding michina.
●Hapana chikonzero chekubvisa HV inotungamira kuyera dielectric kurasikirwa uye capacitance yeCVT.
●Frequency inogona kuchinjwa kuita 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.
Mamiriro ekushanda | -15 ℃ ~ 40 ℃ | RH <80% | ||||||
Anti-kupindira musimboti | Frequency kutendeuka | |||||||
Magetsi | AC 220V±10%, 50/60Hz | Jenereta inogona kushandiswa. | ||||||
High voltage output | AC 0.5KV~10KV (12kV sarudzo) | Imwe neimwe 0.1kV | ||||||
Kururama | 2% | |||||||
Max.current | 200mA | |||||||
Capacity | 2000VA | |||||||
Self-excitation simba | AC 0V~50V/15A | 50Hz, 60Hz imwe frequency 45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Automatic dual frequency | ||||||
Resolution | tgδ: 0.001% | Cx: 0.001pF | ||||||
Kururama | ∆tgδ: ±(kuverenga*1.0%+0.040%) | |||||||
∆C x: ±(kuverenga*1.0%+1.00PF) | ||||||||
Chiyero chiyero | tgδ | Pasina muganhu | ||||||
C x | 15pF <Cx <300nF | |||||||
10KV | Cx <60 nF | |||||||
5KV | Cx <150 nF | |||||||
1KV | Cx <300 nF | |||||||
CVT bvunzo | Cx <300 nF | |||||||
LCR kuyerwa kwemhando | L>20H(2kV) | R>10KΩ(2kV) | ||||||
LCR kuyerwa kwechiyero | 0.1% | Resolution | 0.01 | |||||
CVT chiyero chechiyero | 10 ~ 10000 | |||||||
CVT chiyero chechokwadi | 0.1% | |||||||
CVT chiyero kugadzirisa | 0.01 | |||||||
Insulation resistance | DC high voltage | 5 ~ 10kV | Kururama | ±(2%*Kuverenga +10V) | ||||
IR kururama | 100kΩ-1000GΩ: <5% (yedzo voltage isiri pasi pe250V) 100GΩ-1000GΩ: 10% (yedzo voltage isiri pasi pe10000V) | |||||||
Dimension | Main unit: 350(L)×270(W)×270(H) | |||||||
Bhokisi rekushandisa: 350(L)×270(W)×160(H) | ||||||||
Memory capacity | Mapoka mazana maviri, USB flash disk kuchengetedza inotsigirwa. | |||||||
Kurema | Main unit: 22.75Kg | |||||||
Bhokisi rekushandisa: 5.25Kg |
Tester | 1 set |
Zvishandiso kesi | 1 chidimbu |
HV tsvuku bvunzo inotungamira 8m | 1 chidimbu |
LV dema bvunzo inotungamira 8m | 1 chidimbu |
Tambo yesimba 1.8m | 1 chidimbu |
CVT Inobatanidza mutungamiri 5m | 1 chidimbu |
Ground lead 2m | 1 chidimbu |
Prinda bepa | 2 rolls |
10A fuse | 3 zvidimbu |
Bhuku reMushandisi | 1 kopi |
Factory Test report | 1 kopi |
Optional accessories | |
Oiri Test cell | 1 pc |
Heating controller | 1 pc |
Iine oiri yekuyedza sero uye yekudziya controller, mushandisi anogona kuyedza tan delta ye dielectric fluid senge transformer mafuta.
Heating controller
Oiri mudziyo