GDTL AC Resonant Test System yeJenareta
GDTL yakatevedzana AC Resonant Test System yeJenareta inogona kushandiswa nekugadzirisa inductance ye reactor, kana kugadzirisa nzira yebasa resonant frequency yesystem kuti iwane resonance.Nzira mbiri idzi dzinogona kushandiswa kuwana resonance.Mumagetsi ekusimudzira maitiro, kana iyo resonant point ikatsauka, inogona kuwanikwa chaizvo nenzira yeakanaka tuning frequency, iyo inovimbisa yakakwira Q kukosha uye kuderedza simba remagetsi uye huremu hwehuremu hwemidziyo yekuyedza.
●Saizi diki, uremu hwakareruka kana uchienzaniswa neakaenzana voltage level, yakafanana generator AC inoshingirira voltage test equipment.Single equipment is not more than 60kg, nyore kufamba.
●Yepamberi musimboti weseti yese mudziyo uye nyowani frequency & inductance modulation tekinoroji, nyatso simbisa jenareta simba frequency inomira voltage test zvinodiwa.Wide application scope.
●Yakashongedzerwa ne 20Hz-300Hz inoshanduka yekudzora sosi.Kudzivirirwa kwakanaka uye kubuda waveform, kugadzikana kwakanyanya.Nemaitiro akawanda ekushanda, ari nyore kushanda.
●Simba rekupa 220V kana 380V, yakanakira pane-saiti magetsi ekutsvaga.
●Max.Q poindi inogona kuwanikwa chaizvo nenzira yekutanga inductance modulation uye gare gare frequency modulation, kudzivirira resonance kutsauka nekuda kwekuwedzera voltage;
●Flexible configuration uye kuwedzera kwakasimba.Sangana nezvese capacitive bvunzo yekuyedza chinhu chinodiwa mumagetsi system.
●Power frequency test mode kana Variable frequency test mode.
●Multi-use, inodhura-inoshanda.
●Rated goho voltage: 0 ~ 50kV (RMS) kana pasi.
●Kubuda kakawanda: 45 - 300Hz.
●Waveform: yakachena sine wave, THD ≤ 1%.
●Max.simba: 2000kVA kana pasi.
●Duty kutenderera: kuenderera kushanda 15mins imwe nguva pakuzara kwemagetsi kubuda.
●Quality factor: 10 - 40.
●Frequency kugadzirisa senitivity: 0.1HZ, kusagadzikana kwe <0.05%.
●Simba rekushandisa: 220V kana 380V ± 15%, 50HZ ± 5%.
GDTF- 100/50 | |
Input voltage (V) | 380 |
Kubuda kwemagetsi (kV) | 0- 50 |
Kugona (kVA) | 100 |
Sarudzo yekushandisa | Jenareta-- capacitance pasi 0.07-0.13 μF |
10 kV (300 mm² ) tambo ≤ 1 km | |
Main configurations | 50kV/1A Fixed reactor 1 set |
50kV/1A Adjustable reactor 1 set | |
Capacitive divider 50kV | |
GDTF-150/50 | |
Input voltage (V) | 380 |
Kubuda kwemagetsi (kV) | 0- 50 |
Kugona (kVA) | 150 |
Sarudzo yekushandisa | Jenareta--capacitance pasi 0.13-0.2 μF |
10 kV (300 mm² ) tambo ≤ 1.5 km | |
Main configurations | 50kV/1.5A Fixed reactor 1 set |
50kV/1.5A Adjustable reactor 1 set | |
Capacitive divider 50 kV | |
GDTF- 225/50 | |
Input voltage (V) | 380 |
Kubuda kwemagetsi (kV) | 0- 50 |
Kugona (kVA) | 225 |
Sarudzo yekushandisa | Jenareta--capacitance pasi 0.2-0.27 μF |
10 kV (300 mm ² ) tambo ≤ 2.5 km | |
Main configurations | 50kV/1.5A Fixed reactor 2 seti |
50kV/1.5A Adjustable reactor 1 set | |
Capacitive divider 50 kV | |
GDTF- 360/60 | |
Input voltage (V) | 380 |
Kubuda kwemagetsi (kV) | 0- 60 |
Kugona (kVA) | 360 |
Sarudzo yekushandisa | Jenareta--capacitance pasi 0.27-0.33 μF |
Main configurations | 60kV/2A Fixed reactor 1 set |
60kV/2A Adjustable reactor 1 set | |
Capacitive divider 60kV |